Components (generator), Figure 3. generator components – Multiquip Portable Generator GAC3.6HZ User Manual

Page 17

Advertising
background image

gac3.6hz 60 hz geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 17

cOMpOnents (generatOr)

120V

240V

120

V

OFF

3600

AC CIRCUIT BREAKER

INTERRUPTEUR DE

COURANT PRINCIPAL

GAC-3.6H

POWERED by

Honda Engines

211052

GR PRISE DE

TERRE

AC VOLTMETER

VOLTOMETRE CA

ON

OFF

ON

OFF

MARCHE

MARCHE

INTERRUPTEUR

DE OPERATION

OPERATION

SWITCH

CONTROL

DE RALENTI

IDLE

CONTROL

ARRET

ARRET

NEUTRAL BONDED TO FRAME

NEUTRE MIS A LA MASSE A

LA CARCASSE DU MOTEUR

5

2

3

6

7

8

9

4

1

Figure 3. Generator Components

1.

main Breaker – 2-pole, 15 amp circuit breaker protects

the generator from short circuiting or overloading.

When starting the generator always have circuit

breaker placed in the

OFF position.

2.

idle control switch – The generator is provided with

an automatic idle control device for noise suppression

and reduced fuel consumption. The automatic idle

control automatically engages under a no-load

condition.
With the automatic idle control switched

ON, the

engine revolutions will automatically drop to about

2600 rpm (low-speed operation) within 3 seconds

after the load stops. When the operation is resumed,

the engine speed is automatically increased to about

3600 rpm (high-speed operation) as soon as the load

is connected.

3.

Operation switch – Place switch in ON position (up)

for normal operation. To turn-off the generator, place

switch in

OFF position (down).

4.

ac-voltmeter – Indicates (with a mark) the rated 60 Hz

(single-phase) output voltage. In addition the voltmeter

can also be used as a diagnostic tool. If the voltmeter

indicator (needle) is below the rated voltage, engine

problems may exist (low/high RPM's).
To prevent damage to the generator or power tools

due to low output voltage, turn the generator

OFF and

consult your authorized Multiquip service dealer.

5.

240v Output Receptacle – NEMA L6-20R twist-lock

receptacle will provide 240V @ 20 amps, 60 Hz.

6.

gFci ground – GFCI ground connection point.

7.

120v Output Receptacle – NEMA L5-30R twist-lock

receptacle will provide 120V @ 30 amps, 60 Hz.

8.

gFci duplex Receptacle – NEMA 5-15R, GFCI

receptacle will provide 120V @ 15 amps.

9.

chassis ground – This ground connection point

should be connected to a good earth ground (ground

rod).

Advertising
This manual is related to the following products: