Pump components – Multiquip CENTRIFUGAL PUMP QP2H User Manual

Page 13

Advertising
background image

QP2H CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (08/04/08) — PAGE 13

Figure 2 shows a typical application using the QP2H centrifugal pump. Please note that this pump is intended for the
removal of clean water.

PUMP COMPONENTS

Figure 2. QP2H Pump Application

1. Pump – The QP2H is 2-inch centrifugal pump used in

general de-watering applications. Typical dewatering
applications consist of dewatering basements and
swimming pools.

2. Fill Cap – Prior to operation, the pump casing should

be filled with water. Remove this cap to add water to
the pump. After the initial prime, a sufficient amount of
water will be retained in the casing so that the operator
will not need to re-prime later.

If the casing is dry or has insufficient water, the pump
will have difficulty in priming which could lead to
premature mechanical seal wear thus causing damage
to the pump.

3. Discharge Port – Connect a 2-inch discharge hose to

this port.

4. Worm Clamp – Used to secure the hose to the inlet

and outlet ports on the pump. Use two clamps to secure
the hose on the inlet side of the pump.

5. Discharge Hose – Connect this flexible rubber hose

to the discharge port on the pump. Make sure that the
hose lays flat and is not kinked. Use only recommended
type discharge hose. Contact Multiquip parts
department for ordering information.

6. Suction Port – Connect a 2-inch inlet hose to this

port. Use two worm clamps to secure the hose.

7. Suction Hose – Connect this flexible rubber hose to

the suction port on the pump. Make sure that the hose
lays flat and is not kinked. Use only recommended
type suction hose. Contact Multiquip parts department
for ordering information.

8. Drain Plug – Remove this plug to drain water from the

pump.

9. Strainer – Always attach a strainer to bottom side of

the suction hose to prevent large objects and debris
from entering the pump. Strainer should be positioned
so that it will remain completely under water. Running
the pump with the strainer above water for long periods
can damage pump.

Advertising