350 performance data, 350 specifications, Which xmt – Miller Electric XMT 350 Series User Manual

Page 2: Is right for you, Additional features, Subject to change without notice.)

Advertising
background image

2

Certified to both the Canadian and U.S. Standards for welding equipment.

DUTY CYCLE CHART

DUTY CYCLE

30

WELDING AMPERES

200

150

100

10

15

20

25

500

400

300

100

40

50

60 70

90

80

425

350

250

3-PHASE OPERATION

1-PHASE OPERATION

6 AWG POWER CORD

8 AWG POWER CORD

0

10

20

30

40

50

60

70

80

90

100

0

100

200

300

400

500

AMPS

VOLTAGE

GTAW
MIN

SMAW

80A

ARC
CONTROL

50%

75%

100%

25%

0%

SMAW
MAX

GTAW
MAX

CC VOLT/AMP CURVE

0

10

20

30

40

50

60

70

80

90

100

0

100

200

300

400

500

AMPS

VOLTAGE

MAX

MIN

CV VOLT/AMP CURVE

XMT

®

350 Performance Data

Input
Power

Three-
Phase

Single-
Phase

Rated Out put
at 60%
Duty Cycle

350 A at
34 VDC

300 A at
32 VDC

Amperage
Range in
CC Mode

5 – 425 A

5 – 425 A

Voltage
Range in
CV Mode

10 – 38 V

10 – 38 V

Max. Open-
Circuit
Voltage

75 VDC

75 VDC

Amps Input at Rated Load Output, 60 Hz,
208 V 230 V 400 V 460 V 575 V KVA KW

40.4

36.1

20.6

17.8

14.1

14.2 13.6

60.8 54.6

29.7

24.5

19.9

11.7 11.2

Weight

80 lb
(36.3 kg)

Dimensions

H: 17 in (432 mm)
W: 12-1/2 in (318 mm)
D: 24 in (610 mm)

Amperage
Class*

300 A

350 A

565 A

Power
Processing

Auto-Link

®

Auto-Line

Manual

Remote
Capability

Yes

Yes

Yes

No

Yes

Industrial Inverters

XMT 304 CC/CV, 230/460 VAC

XMT 350 MPa, 208 – 575 VAC

XMT 350 CC/CV, 208 – 575 VAC

XMT 350 VS, 208 – 575 VAC

XMT 456 CC/CV, 230/460 VAC

Process
Capability

Stick,
DC TIG,
MIG,
CAC-A

Pulsed MIG Capability

Optima

Pulse Control Required

Built-In

Optima

Pulse Control Required

No

Optima

Pulse Control Required

Connectors

Dinse only

Dinse or Tweco

Dinse or Tweco

Tweco only

Ring Lug only

For more
Information

Lit. No. DC/18.8

Page 4

Page 3

Page 3

Lit. No. DC/18.8

Auxiliary
Power

Optional

Optional

Optional

No

Standard

XMT

®

350 Specifications

(Subject to change without notice.)

Which XMT

®

is Right for You?

Additional Features

Exceptional electrical efficiency. At 400 A,
efficiency is 87.24%!

350 A of welding output at 60% duty cycle
with superior low-end performance.

Power factor of .95 enables smaller
fuses/breakers and primary wiring. Primary
amperage draw at rated output is 25% less
than the competition.

Ultra-tough, polycarbonate-blended cover
for control panel
protects front controls
from damage.

Optional gas solenoid for TIG welding.

Which XMT 350
is right for you?

See XMT 350 CC/CV

(page 3)

YES

NO

YES

NO

See XMT 350 MPa

(page 4)

See XMT 350 VS

(page 3)

Need Pulsed MIG

(GMAW-P)

capability?

Most often Stick (SMAW)

or Flux Cored (FCAW) welding

with a voltage-sensing

feeder?

*60% Duty Cycle Rating

Advertising