Miller Electric Big Blue 602P User Manual

Page 26

Advertising
background image

OM-491 Page 22

Return To Table Of Contents

5-10. Connecting To Remote Amperage Adjust Receptacle RC13 On CC Models

Ref. 154 862-A / 048 720-K / 802 160-E

1

Remote Amperage Adjust
Receptacle RC13

Connect optional remote control to
RC13 (see Section 6-3).

1

5-11. Connecting To Remote 14 Receptacle RC14 On CC/CV Models

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit
breaker CB5.

24 VOLTS AC

B

Contact closure to A completes
24 volt ac contactor control
circuit.

New! LDR-14 long

C

Output to remote control:+10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.

New! LDR-14 long

distance remote

(includes 120 V

receptacle)

REMOTE

OUTPUT

CONTROL

D

Remote control circuit common.

receptacle)

OUTPUT

CONTROL

E

DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.

OR

115 VOLTS AC

I

115 volts, 10 amperes, 60 Hz
ac. Protected by circuit breaker
CB6.

J

Contact closure to I completes
115 volt ac contactor control
circuit.

802 169-F

GND

K

Chassis common.

NEUTRAL

G

Circuit common for 24 and 115
volt ac circuit.

*The remaining sockets are not used.

Advertising