REAR PANEL DESCRIPTION

POWER Switch

Switch up to turn the FUSSION 3000

on, and switch down to turn it off. Make
sure the signal source’s level control is
down before you turn it on.

POWER/PROTECT Indicator

When the

POWER switch is turned on,

and the linecord is connected to an active
AC Mains supply, this indicator lights green
to let you know that you’re ready to rock
and roll. If one of the protection circuits in
the FUSSION 3000 should trigger, this indi-
cator changes to red. The protection circuits
include RMS limiting on the input and
thermal protection on the heatsink. If the
output begins to clip for more than a few
seconds, the

POWER/PROTECT indicator

changes to red and the RMS limiting pro-
tection circuit discretely reduces the input
signal until the output is just below clip-
ping. If this should happen, turn down the
level at the source (mixing console) until
the

PROTECT light changes back to green.

If the thermal protection circuit should

get activated, the

POWER/PROTECT indicator

changes to red and the amplifiers shut down
until the heatsinks cool to a safe operating
level. Once the amplifier cools, the thermal
protection circuit resets and normal opera-
tion resumes. You should determine what is
causing the overheating condition and take
steps to remedy it (i.e., direct sunlight on
the heatsink, not enough clearance for air
to circulate freely around the heatsink, etc.).

AC Receptacle

This is where you connect the AC

linecord to provide AC power to the
FUSSION 3000’s built-in power amplifiers.
Plug the linecord into an AC socket prop-
erly configured for your particular model.

The FUSSION 3000 is shipped with a

connector that mates with the AC recep-
tacle on the rear panel. Use heavy gauge
wire for the linecord to avoid power losses
across the wire. (See page 8 for more info.)

The bar

A

on the rear panel is there to

secure the linecord and prevent it from acci-
dentally getting pulled loose from the AC
receptacle. Wrap the linecord through the
bar and tie it in a knot to secure it.

Note:

You can change the AC voltage

configuration from 115V to 230V internally
by reconfiguring the transformer primary
wiring on the power supply board. Contact
Mackie Technical Support for instructions
(1-800-258-6883).

FUSE

Always replace the fuse with the type in-

dicated on the rear panel. Never replace the
fuse with one of a higher value than indi-
cated on the rear panel.

WARNING: Make sure
you use the correct fuse
relative to the AC operat-
ing voltage.
115VAC=16A Slow-Blow
230VAC=10A Slow-Blow

FUSE

3000

FUSSION

WARNING:

THIS SURFACE MAY REACH HIGH TEMPERATURE DURING

STANDARD USE. TO ENSURE PROPER OPERATION ALLOW A MINIMUM OF 6 INS.
OF CLEARANCE FROM THIS SURFACE AND ADEQUATE VENTILATION. TO REDUCE
THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED
COMPONENT. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

RISK OF ELECTRIC SHOCK

DO NOT OPEN

REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE

UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE

CAUTION

AVIS:

RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR

SERIAL NUMBER

MANUFACTURING DATE

FS

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC, WOODINVILLE, WA, USA

AND MACKIE EUROPE • MANUFACTURED IN ITALY • COPYRIGHT ©1998 •

THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC.:

"MACKIE", AND THE "RUNNING MAN" FIGURE • PATENT PENDING

10

0

MAIN INPUT

LOOP OUT

PIN 1- GND / PIN 2- POS (+) /

PIN 3- NEG (-)

HIGH PASS

85Hz - 20kHz

FULL RANGE
55Hz - 20kHz

POWER (GREEN)
PROTECT (RED)

FILL OUT

85Hz - 20kHz

OUTPUT

LEVEL

SUB-OUT

20Hz - 85Hz

PHASE

180˚

MAIN INPUT

ON

FUSE

16A / SB

NEMA LS-20 20A-115VAC

PARALLEL

115VAC Version

FUSE

ON

FUSE

10A / SB

10A - 230 VAC