8

Hardware Settings Page

The

Hardware Settings page provides access to master clock settings, sample rate

settings, buffer settings and more.

Master Clock

This section selects the source of the master clock. Internal (default setting) selects the
Audiophile 192’s internal clock, while S/PDIF In selects the clock received through the
S/PDIF input stream.

If Internal is selected, the status display will always show Locked. If S/PDIF is selected,
the display will only show “Locked” when a valid S/PDIF signal is detected at the input.
It will display “Unlocked” if there is no valid S/PDIF input. When syncing to any external
clock source, the sample rate must be selected manually on this page.

Codec Sample Rate

This section displays the sample rate as it was set in your last-opened DAW
application.

S/PDIF Sample Rate

When you attempt to sync to an external clock via S/PDIF, you must select the sample
rate that your external clock source is using manually on this page.