Introduction


This document describes the configuration of Mitel Networks PBX’s to correctly
interface to the Interactive Group Communication System by VCon. For more
information on the configuration of the IGC, please refer to Mitel 3300 -
RemoteAbility IGC Integration Specifications V1.
Note that all PBX configuration
should be undertaken by a qualified Technician.

3300ICP with ISDN or SX2000 with ISDN

Attach VCon IGC server T1 link to NSU, DSU or Embedded PRI card

o

Configure hardware for Line Termination through jumpers or DIP

switch – please refer to the Technician’s Handbook of the correct
product (3300 or SX2000)

connect to server with a straight through cable

Program trunks

o

for example, please see Example of T1 PRI programming on 3300

Program PRI link characteristics though IMAT (for NSU or DSU) or

through ESM (embedded PRI card in 3300ICP)

o

Protocol used is DMS-250, user side

Reset NSU or PRI card to allow new configuration to load

Test link to server by dialing <feature access code for individual trunk

access> <trunk number><any 4 digit number>< # > e.g.
<**2><6101><1000><#>

o

You should hear “Welcome to Remoteability”

Program ARS so that a single four digit number accesses the IGC system

o

Program trunk group

o

Add trunks to trunk group

o

Create Digit Modification Assignment

o

Create Route Assignment

o

Create ARS Digits Dialed Assignment

o

Please see Example of ARS Programming on 3300 or SX2000

Example of T1 PRI programming on 3300 or SX2000

Class Of Servic e – changes from default values


Public Network Access via DPNSS

Yes