1.Specifications

Cable Required: Category 5, 5e, 6 shielded or unshielded twisted pair

Compliance:
CE; FCC Class A, IC Class/class A

Video Support:
to UXGA (1600x1200 @ 70Hz), RGBHV, RGB, Composite, S-

Video, Component Video modes

Maximum
Resolution and
Refresh Rate:
At 250 ft. (76 m) or less, 1600 x 1200 at 70 Hz

Required Source
Impedance:
Video OUT: 75 ohms;
Audio OUT (if any): 600 ohms maximum

Required Destination
Impedance:
Video IN: 75 ohms;
Audio IN (if any): 600 ohms minimum

Audio
Characteristics:
Channels: Right/Left summed;
Line Level 600 Ohm Unbalanced

Connectors: (1) 3.5-mm, (1) RJ-45, (1) HD15 F

Temperature
Tolerance:
Operating: 32 to 104°F (0 to 40°C);
Storage: -4 to +140°F (-20 to +60°C)
Humidity
Tolerance:
Up to 80% noncondensing

Enclosure:
Steel

Power:
+5 VDC @ 260 mA max

Consumption: 1.3 watts maximum

Size:
0.88 "H x 3.12"W x 3.75"D (2.2 x 7.9 x 9.5 cm)

Weight:
0.56 lb. (0.26 kg)

CHAPTER 1: Specifications

3

.

11

4

2. Introduction

2.1 Overview

Magenta’s MultiView™ CAT5 Video System MultiView series extends VGA and
audio signals over ordinary Category 5 cable.

This manual covers the Magenta MultiView™ 250A CAT5 Video System Series
Receiver with Audio.

For information on the respective transmitter unit, please refer to the appropriate
manual included with the transmitter.

WARNING

This equipment is not intended for, nor does it support, distribution

through an Ethernet network. Do not connect these devices to any sort

of networking or telecommunications equipment!

2.2 Equipment You May Also Need

• 1/8” (3.5mm) Audio cable with RCA jacks.
• Video cable with HD15 connectors.
• CAT5 cable.


2.3 Compatible Cabling

CAT5 cabling for the MultiView™ Series must be pinned to the T568B wiring
specification (see appendix A). We also highly recommend that all CAT5 cables
be pre-terminated and tested. Cables terminated on-site or in an existing
infrastructure should be tested before use to ensure compliance with the T568B
specification. Using incorrectly terminated CAT5 cables can damage the Magenta
MultiView™ Series.