3. connecting torch – Miller Electric DB1712RDI25 User Manual

Page 9

Advertising
background image

OM-1600 Page 5

3-3. Connecting Torch

A. Connecting Torch With One-Piece Cable

Y Turn Off welding power

source power before install-

ing torch.

Obtain the following hose:
1

Gas Hose With 5/8-18 Right-

Hand Fittings

Connections:
2

Regulator/Flowmeter

3

Gas Cylinder

4

Welding Power Source

5

Gas Valve

Operating Torch Gas Valve:
Valve controls gas preflow and post-

flow. Open valve on torch just before

welding.
Preflow is used to purge the immedi-

ate weld area of atomsphere.
Postflow is required to cool tungsten

and weld, and to prevent contamina-

tion of tungsten and weld. After weld-

ing, leave valve open about 1 sec-

ond for every 10 amperes of weld

current. Close valve on torch when

postflow is finished.
6

One-Piece Torch Cable

7

Power Cable Adapter

Connect gas hose and power cable

to adapter before connecting adapt-

er to weld output terminal.
8

Work Clamp

Connect work clamp to clean, paint-

free location on workpiece, close to

weld.
Use wire brush to clean weld joint

area.
9

Foot Control

803 313

If applicable, install high-frequency unit.

Tools Needed:

5/8, 7/8 in

1

2

3

5

Torch Without Gas Valve

4

8

7

6

1

2

3

4

5

6

7

8

Torch With Gas Valve

9

9

Advertising