MITSUBISHI ELECTRIC FR-S520E User Manual

Page 113

Advertising
background image

103

Terminal function selection parameters

2

F

UNCT

IO

NS

<Setting>

Refer to the following table and set the parameters:

*1.When Pr. 59 = "1 or 2", the functions of the RL, RM and RH signals change as

listed above.

*2.Actuated when the relay contact "opens".
*3.When using the REX signal, an external command cannot be used to make a

reverse rotation start.

Setting

Signal

Name

Functions

Related Parameters

0

RL

Pr. 59 = "0"

Low-speed operation

command

Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87

Pr. 59 = "1", "2" (*1)

Remote setting

(setting clear)

Pr. 59

1

RM

Pr. 59 = "0"

Middle-speed

operation command

Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87

Pr. 59 = "1", "2" (*1)

Remote setting

(deceleration)

Pr. 59

2

RH

Pr. 59 = "0"

High-speed operation

command

Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87

Pr. 59 = "1", "2" (*1)

Remote setting

(acceleration)

Pr. 59

3

RT

Second function selection

Pr. 44 to Pr. 47, H7

4

AU

Current input selection



5

STOP

Start self-holding selection



6

MRS

Output shut-off stop



7

OH

External thermal relay input (*2)
The inverter stops when the externally
provided thermal relay for overheat
protection, motor's embedded temperature
relay etc. is actuated.

Refer to page 164.

8

REX

15-speed selection (combination with 3
speeds RL, RM, RH) (*3)

Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87

9

JOG

Jog operation selection

Pr. 15, Pr. 16

10

RES

Reset

Pr. 75

14

X14

PID control presence/absence selection

Pr. 88 to Pr. 94

16

X16

PU-external operation switch-over

Pr. 79 (setting: 8)

- - -

STR

Reverse rotation start

(can be assigned to STR
terminal (Pr. 63) only)

REMARKS

•One function can be assigned to two or more terminals. In this case, the function is activated

when one of the multiple terminals used for assignment turns on.

•The speed command priorities are higher in order of jog, multi-speed setting (RH, RM, RL,

REX) and AU.

•Use common terminals to assign multi-speeds (7 speeds) and remote setting. They cannot

be set individually.
(Common terminals are used since these functions are designed for speed setting and need
not be set at the same time.)

Advertising
This manual is related to the following products: