Motion Actuator User Manual

Page 16

Advertising
background image

Loosen the two fixings on the cable clamp.

Pull the cable out through the cable gland.

Replacement

Re-fitting is the reverse of the removal procedure.

Feed the new cable(s) through the cable
gland.

Connect the cable(s) including the earth
lead.

Tighten the cable retaining clamp.

Take care not to damage the sealing
gasket on the termination box when
replacing the cover.

Replace the fixings according to the record
made when they were removed.

Tighten the four M3 fixings to a torque of
0.7 Nm.

Page 10

Chapter 3

ServoTube 38 Installation Guide

Maintenance

POWER CABLE

M3 FIXING SCREWS (4 OFF)

SENSOR CABLE

POD LID

POD

MICRO CONNECTOR
ON PCB, PL1

SENSOR CABLE

POWER CABLE

CABLE
GLAND

SCREW TERMINAL
CONNECTOR, TB1

Figure 3.1 - Power and Sensor cable connection details in the pod