Meyer Sound UPJunior User Manual

Page 11

Advertising
background image

ultracompact VariO loudspeaker

10 No automatic turn-off voltages. Voltages

above 265 V AC are fuse protected but
may cause permanent damage to the
power supply. Voltages below 90 V AC
may result in intermittent operation.

11 Current draw for a single loudspeaker.

Loop out not used.

AC POWER

AC power connector

PowerCon with looping output

Voltage selection

Automatic

Safety agency rated operating voltage

100 V AC – 240 V AC, 50/60 Hz

Turn on/turn off points

10

90 V AC – 264 V AC, 50/60 Hz

CURRENT DRAW

11

Idle current

0.448 A rms (115 V AC), 0.285 A rms (230 V AC), 0.497 A rms (100 V AC)

Max. long-term continuous current (>10 sec)

2.55 A rms (115 V AC), 1.55 A rms (230 V AC), 2.75 A rms (100 V AC)

Burst current (<1 sec)

2.9 A rms (115 V AC), 1.7 A rms (230 V AC), 3.2 A rms (100 V AC)

Ultimate short-term peak current draw

12.0 A peak (115 V AC), 9.0 A peak (230 V AC), 13.0 A peak (100 V AC)

Inrush current

15.0 A peak (115 V AC), 13.0 A peak (230 V AC), 15.0 A peak (100 V AC)

PHYSICAL

Enclosure

Premium birch plywood

Finish

Black textured

Protective grille

Powder-coated hex-stamped steel

Rigging

QuickFly rigging options

Dimensions

9.00 w x 19.04 h x 10.20 d (228.60 mm x 483.55 mm x 259.08 mm)

Weight

28 lbs (12.70 kg)