3) Control sequence

(1) Send the command from the personal computer to the projector. (The commands shall be sent at intervals

of at least 400ms.)

(2) The projector will send a return command 400ms* after it receives an end code. If the command is not

received correctly, the projector will not send the return command.

(3) The personal computer checks the command and confirms if the sent command has been executed or not.
(4) This projector sends various codes other than the return code. When having a control sequence by RS-

232C, reject other codes from the personal computer.

* :

The sending time of return command may delay depending on the (operating conditions) during changing
the input signal, etc.

[Example] When turning the power ON (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

Status code from

Description

from the PC, etc.

the projector

30 30 21 0D

Command for POWER ON

'0' '0' '!' '

'

30 30 21 0D

Command receipt confirmation

'0' '0' '!' '

'

(Command echo back)

Sending commands

Status code from

Description

from the PC, etc.

the projector

30 30 5F 72 31 0D

Command for setting the input

'0' '0' '_' 'r' '1' '

'

signal to COMPUTER 1

30 30 5F 72 31 0D

Command receipt confirmation

'0' '0' '_' 'r' '1' '

'

(Command echo back)

Operation

ASCII

HEX

Note

POWER ON

!

21h

This command will not be executed for 1 minute after the power is turned off.

POWER OFF

"

22h

This command will not be executed for 1 minute after the power is turned on.

INPUT COMPUTER 1

_r1

5Fh

72h

31h

This command will not be executed in Stand-by mode or the MUTE is executed.

INPUT COMPUTER 2

_r2

5Fh

72h

32h

This command will not be executed in Stand-by mode or the MUTE is executed.

INPUT VIDEO 1

_v1

5Fh

76h

31h

This command will not be executed in Stand-by mode or the MUTE is executed.

INPUT VIDEO 2

_v2

5Fh

76h

32h

This command will not be executed in Stand-by mode or the MUTE is executed.

• Any commands will not be executed for 10 seconds after the power is turned on.

4) Operation commands

The operation commands are used for the basic operation setting of this projector. They may not be executed
while the signals are changed. The operation commands have no data codes.

[Example] When setting the input signal to COMPUTER 1 (Figures and symbols enclosed in quotation

marks are ASCII codes.):

5) Volume commands

(Not executable in stand-by mode, while the Splash screen is projected or the MUTE is executed.)

The volume commands are used for the volume setting of this projector with the value.

[Example] When setting the volume to 15 (standard value) (Figures and symbols enclosed in quotation

marks are ASCII codes.):

Sending commands

Status code from

Description

from the PC, etc.

the projector

30 30 56 4C 31 35 0D

Command for setting the volume

'0' '0' 'V' 'L' '1' '5' '

'

30 30 56 4C 31 35 0D

Command receipt confirmation

'0' '0' 'V' 'L' '1' '5' '

'

(Command echo back)

ITEM

ASCII

HEX

VALUE

VOLUME

VL

56h

4Ch

00 - 31

How to set the grade

Use the ASCII codes to set the grade for setting data. Please refer to the table below for the HEX code.

ASCII

'0'

'1'

'2'

'3'

'4'

'5'

'6'

'7'

'8'

'9'

HEX

30h

31h

32h

33h

34h

35h

36h

37h

38h

39h