Mr-g50j-nz (1) troubleshooting with self-check, 2 flowchart of self-check – MITSUBISHI ELECTRIC Mitsubishi Home Refrigerator MR-G50J-SS-NZ User Manual

Page 14

Advertising
background image

14

MR-G50J-NZ
(1) Troubleshooting with self-check

This refrigerator has self-check feature to clarify and indicate where & what the trouble is.
You can perform operation checks and identify malfunction of electric or electronic parts.
Error history is recorded and can be displayed by the refrigerator.

6-2 FLOWCHART OF SELF-CHECK

A

Self-check

Error history mode (Refer to 6.1(8))
Problem may recover automatically.
Perform the following if error is not displayed
before treatment or the error which was displayed
at the time power of the unit was turned on is not displayed.

Operate the ice-making test.
(Current displayed error: Refer to

1

in the table below.)
The display of ice making compart-
ment setting will blink during the test.

c

D

D

Self-check

Plug the power cord into outlet.
(Current displayed error:
Refer to

2

in the table below.)

Locate the trouble according to LED
indication. (See page 15,16)

Is error displayed?

Is error displayed?

Is error displayed?

Release error displayed
mode, and the self-check
is finished.

Release error display
mode and perform the
self-check again.
(go to

A

)

Note1: Self-check cannot detect abnormalities in the following parts.

See page 19-31 for troubleshooting.
Door switch
Motor damper
Heater (Water pipe / Vegetable compartment heater, etc.)
Water pump motor

Note2: If any abnormality is found when switch is turned on, compressor

and fan motor are suspended for 10 minutes.

Note3: The alarm beeps when some abnormalities (motor-locked) have

occurred at the refrigerator fan motor restarts its normal operation.

Note4: If any abnormality occurs in compressor's inverter circuit,

the compressor and the refrigerator fan motor stop for 10 minutes
(not only when plugging the power cord).

Yes

No

Is error displayed?

Was more than one error

displayed during repair?

No

Yes

No

Yes

No

Yes

Yes

Yes

During the ice-making
test mode, watch the
operation ice-maker
gear box and water
pump in refrigerator.

*Wait 10 minutes
before inserting
the cord once
it's unplugged.
(if the cord is
plugged in within
10 minutes, error
may be displayed.)

B

Unplug the power cord from outlet.

Repair /replace defective part(s)
according to LCD indication.

Self-check is finished.

Set the error display mode.

Reset the error history.

(Refer to 6.1(8))

Perform self-check
procedures

B

through

C

.

Perform error
history mode.

No

No

Was the error which was

displayed at the service-call received

was turned on displayed?

Was treatment performed?

Perform error
history mode.

D

Self-check and error display method and operation

Release of self-check display mode

self-check finishes automatically. Error cord display is automatically released 10 minutes later.

Operation method

Display or self-check operation

Display time

Others

Item

1

Ice making test operation.

All items except (*6) listed
up on the table at page
17 will be checked.

1.Conduct the automatic ice making test.

(The display of ice making compartment
setting is blinked)

2.When trouble is found, all error codes

except

e50

-

e55

are displayed.

3.When error is not found, nothing is

displayed.

For 10 minutes
after setting.

Self-check is not available
during child lock, cooking
timer, changing the rotati-
onal speed of compressor,
checking the temperature
of thermistor, damper ope-
ration and demonstration
modes.

Self-check is not available
during child lock, cooking
timer, changing the rotati-
onal speed of compressor,
checking the temperature
of thermistor, damper ope-
ration and demonstration
modes.

Self-check is not available
during demonstration
mode.

For 10 minutes
after power is
supplied.

For one hour
after setting,
or until mode
is released.

1.When trouble is found, all trouble except

e50

-

e55

and displayed.

2.When error is not found, nothing is

displayed.

1.When trouble is found, all trouble except

e50

-

e55

and displayed.

2.When error is not found, nothing is

displayed.

Press the switch.

for 5 seconds.

Plug the power
cord into outlet.

Refer to 6.2(3)
Error history
display mode.

2

Power input.

All items except (*6) listed
up on the table at page
17 will be checked.

3

Error history

(current displayed error)

Self-check

Display error

history.

OA090-1.qxp 06.7.20 9:55 AM Page 14