Description

MeCAN™ is a compact, encapsulated interface module that
translates resistive sender, fault switch and speed signals into
SAE J1939 CANbus data. MeCAN allows quick and simple
integration of ‘mechanical’, non-ECU engines into modern
CANbus systems. Applications include the retrofit of older
engine fleets with digital instruments, controls and telemetry,
and the development of standard control panels for both ECU
and non-ECU engines.

MeCAN has four inputs. Two inputs are for oil pressure and
coolant temperature sensing, either by fault switches or resistive
senders. One input is for engine speed sensing, using a
magnetic pickup or charge alternator. Input signals are
translated into SAE J1939 CANbus messages with appropriate
PGN address, data scaling and transmission rate.
A fourth input is for the connection of a speed calibration
potentiometer during setup mode only. DIP switches allow
selection of normal/setup mode and two speed input ranges.
An LED gives indication of operating mode and CANbus
activity.
Two standard versions allow use with a speed input and
either fault switches or Murphy ES series resistive senders:
part number

model/description

79.70.0014

MEC300-1 MeCAN I/O module, for use with
Murphy ES pressure & temperature senders

79.70.0020

MEC300-2 MeCAN I/O module, for use with
pressure & temperature switches (closing to
negative DC on fault)

Custom solutions are also available for non-standard, volume
OEM requirements.
MeCAN is compact and light enough for inclusion in many
wiring harnesses, but can also be surface mounted via four
fixing holes. The case is fully sealed in epoxy resin for high
impact and environmental resistance.

MeCAN™

Mechanical Engine to CAN J1939 interface

Installation Instructions

00-02-0665

28th November 2008

catalogue section 78

Please read the following information before installing. A visual inspection of this product for damage during

shipping is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical

technicians install this product. If in doubt, please contact your local Murphy representative.

GENERAL INFORMATION

Product specification

power supply:

MEC300-1

(79.70.0014)

MEC300-2

(79.70.0020)

operating voltage

7 to 35 VDC

current consumption

25mA (typ.)

Inputs:

max. operating range

–2 to +35 VDC

oil pressure, coolant temp

sender, Murphy

ES series

switch, closed to
negative on fault

speed input

10 – 60 VAC peak,

adjustable 10 – 180 pulses per rev

speed calibration

0 – 5 kOhm potentiometer

output:

CANbus

SAE J1939 protocol,

120 Ohm terminating resistor fitted.

physical:

case material

high-impact ABS, epoxy filled

case dimensions (l x w x h)

100 x 25 x 15 mm / 4.0 x 1.0 x 0.6 in

weight

approx. 60g / 0.13 lb

operating temperature

–20°C to +85°C / -4°F to +185°F

environmental sealing

IP65 case (with DIP switch film

intact), exposed lead ends

electromagnetic compatibility