Murphy Pull/Push DC Solenoids RP2310B User Manual

Pull/push dc solenoids for diesel engines, Rp series, One solenoid for pull/push operation

Advertising
background image

RPS-00092B page 1 of 4

MODEL & PART NUMBERS:

DC SOLENOIDS & ACCESSORIES

SHIPPING WEIGHT

Model No.

Description

ozs (kg)

RP2307B

12 VDC, 1 in. (25 mm) stroke, 11 lbf (49 N) pull, 23 lbf (102 N) hold

24 ozs (0.7 kg)

RP2308B

24 VDC, 1 in. (25 mm) stroke, 11 lbf (49 N) pull, 23 lbf (102 N) hold

24 ozs (0.7 kg)

RP2309B

12 VDC, 1-1/2 in. (38 mm) stroke, 14 lbf (62 N) pull, 34 lbf (151 N) hold

48 ozs (1.4 kg)

RP2310B

24VDC, 1-1/2 in. (38 mm) stroke, 14 lbf (62 N) pull, 34 lbf (151 N) hold

48 ozs (1.4 kg)

65-01-0108

Clevis yoke assembly

1 ozs (.03 kg)

65-01-0110

Clevis yoke chain assembly

2 ozs (.04 kg)

40-05-0315

Threaded rod (1-1/2 in.)

.05 ozs (.001 kg)

00-00-2457

RPS in-line ball joint

.05 ozs (.001 kg)

00-00-2458

RPS 90° ball joint

1 ozs (.03 kg)

RP Series

One Solenoid For Pull/Push Operation

No Internal Switches

Reduce Coil Burnout

Boost Reliability

Reduce Adjustments

High Force–Small Size

Can Be Used With Most Engines
Start Systems

SD85 Solenoid Drive Time Delay
Available To Greatly Reduce Possibility
Of Coil Burnout And Facilitate Low
Current Piloted Operation.

RP2307B & RP2308B

RP2309B & RP2310B

RPS-00092B

Revised 11-03

Catalog Section 40

(00-02-0107)

Pull/Push DC Solenoids for

Diesel Engines

Description

Murphy push/pull DC Solenoids
provide single unit versatility for engine
applications, such as shutdown.

A choice of two models and two
voltages is available. All models come
complete with return spring and rubber
seal boot. See the next page for
specifications and options.

Basic Models

Models RP2307B and RP2308B give a
full one inch (25 mm) stroke at 11
pounds (49 N) and hold up to 23 pounds
(102 N) at full voltage, continuous duty.

They will operate at any stroke less than
maximum; refer to the chart shown on
page 2.

Models RP2309B and RP2310B can
pull 14 pounds (62 N) with a one-and-a-
half inch (38 mm) stroke. They hold up
to 34 pounds (151 N) at full voltage,
continuous duty. See the chart on page 2
for holding force at any stroke less than
maximum.

SD85 Solenoid Drive
Time Delay

Using the SD85 ensures the energize
coil is only powered for 1-2 seconds

with each operation. If the plunger does
not seat in that time, it is highly
unlikely it will seat. The hold coil is
energized as long as the signal to the
SD85 is active. This insures long life of
the RP solenoid.

Warranty

A limited warranty on materials and workmanship
is given with this FW Murphy product. A copy of
the warranty may be viewed or printed by going
to www.fwmurphy.com/support/warranty.htm

Advertising