English – Middleby Marshall PS360-U User Manual

Page 17

Advertising
background image

17

ENGLISH

SECTION 3 - OPERATION

III. QUICK REFERENCE: DIGITAL TEMPERATURE CONTROLLER

Display

Shows the Set Point or

the Actual Tempera-

ture in degrees Fahr-

enheit (F) or Celsius

(C).

"SP LOCK" Light

Lights when the set

point is locked out

from changes. This

setting can only be

changed by service

personnel.

OVERTEMP Light

Lights when the oven

temperature is greater

than 343°C. Refer to

Quick Reference:

Troubleshooting in

this section.

Temperature Key

Press this key once to

view the Actual Tem-

perature in the Dis-

play.

Unlock Key

Press this key together

with the Set Point Key

to allow the Set Point

to

be

changed.

Changes can only be

made for 60 seconds.

Up Arrow and Down Arrow

Keys

Press these keys to adjust

the Set Point up or down. If

the Set Point will not

change, refer to Set Point

Key and Unlock Key in this

section.

Set Point Key

Press this key together

with the Unlock Key to

allow the Set Point to

be changed.

Changes can only be

made for 60 seconds.

Service Key

For use by ser-

vice personnel

only.

"ACTUAL TEMP"

Light

Lights when the

Actual Tempera-

ture is shown in

the display.

"SET PT" (setpoint)

Light

Lights when the set

point is shown in the

display.

"HEAT ON" Light

Lights when the

burner or heating ele-

ments, as appropriate

for the oven model,

are in operation.