Architects and engineers’ specifications, Frequency response graph – MACKIE SA1521 User Manual

Page 10

Advertising
background image

10

Architects and Engineers’ Specifications

Thermal protection shall be provided by

a thermal sensor mounted on the heatsink,
which monitors the heatsink temperature
and triggers the thermal protection circuit
should the temperature exceed 140º F
(60º C). The thermal LED shall light and
the input signal shall be muted until the
heatsink cools to a safe operating level, at
which point the thermal protection circuit
auto-resets and normal operation resumes.

Overload protection shall be provided by

a limiter circuit, which monitors the low-
frequency amplifier output and reduces the
input level to the amplifier should the am-
plifier output begin to clip.

The loudspeaker enclosure shall have a

trapezoidal shape and shall incorporate two
side handles and a top and bottom relocation
handle. The enclosure shall be constructed
of a combination multi-ply wood and high-
pressure injected structural resin, with a black
PVC vinyl finish. The front of the loudspeaker
shall be covered with a powder coated,
weather-resistant perforated steel grille.

The active two-way full-range loudspeaker

system shall be a Mackie SA1521.

Dimensions

32.0 in/

81.3 cm

13.9 in/

35.3 cm

18.1 in/

46.0 cm

19.1 in/

48.5 cm

19.1 in/

48.5 cm

WARNING: THIS SURFACE MAY REACH HIGH TEMPERATURE DURING

STANDARD USE. TO ENSURE PROPER OPERATION ALLOW A MINIMUM OF 6 INS.
OF CLEARANCE FROM THIS SURFACE AND ADEQUATE VENTILATION. TO REDUCE
THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED
COMPONENT. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

RISK OF ELECTRIC SHOCK

DO NOT OPEN

REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE

UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE

CAUTION

AVIS: RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR

SERIAL NUMBER

MANUFACTURING DATE

ON

POWER

115V AC FUSE AC125V-T6.3A

POWER

THERMAL

SIGNAL

LIMIT

LOOP OUT

MAIN INPUT

PARALLEL

0dB

-15

+5

SA1521

CONCEIVED AND DESIGNED BY MACKIE DESIGNS INC, WOODINVILLE, WA, USA

AND MACKIE EUROPE • COPYRIGHT ©2001 •

THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC.:

"MACKIE", AND THE "RUNNING MAN" FIGURE • PATENT PENDING

ACTIVE SOUND REINFORCEMENT

SPEAKER SYSTEM

FREQUENCY RESPONSE GRAPH

The active two-way, full-range loudspeaker

system shall incorporate one 15-inch
low-frequency (LF) transducer and a 1-inch
exit compression driver high-frequency
(HF) transducer. The LF driver shall be
mounted in a vented enclosure tuned for
optimum low-frequency response. The HF
transducer shall be loaded on a symmetrical
constant directivity horn.

The system shall have a nominal coverage

pattern of 75

° (horizontal) x 65° (vertical).

System frequency response shall vary no
more than

± 3 dB from 57Hz to 18kHz

measured on axis. The loudspeaker shall in-
corporate a Class G low-frequency amplifier
capable of delivering 400 watts RMS over a
frequency range of 20Hz–1300Hz. The sys-
tem shall incorporate a Class AB 100 watt
RMS amplifier specifically designed to power
the HF driver over the range of 1300Hz –
20kHz. The amplifiers shall be mounted on
an aluminum heatsink, which shall be
mounted on the rear of the speaker system,
and shall be convection cooled.

Advertising