St-3050d submersible pump, Operation – Multiquip Submersible Pump ST-3050D User Manual

Page 24

Advertising
background image

PAGE 24 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)

ST-3050D SUBMERSIBLE PUMP

OPERATION

Operation

1. Attach a suitable lifting cable (rope) to the carrying handle

(Figure 16) on the pump and lower the pump into place. For
applications where there is an excessive amount of mud, grit
or silt, the use of a support platform is desirable. When
pumping water from swimming pool type applications where
there is little or no debris, the support platform is not required.

2. Make sure the pump is always placed in an upright position,

not tilted (Figure 17). Never position the pump directly on a
soft, loose bottom. Remember to attain maximum pumping
capacity and prevent excessive wear, position the pump so
it will not burrow itself into sand or clay.

SUBMERSIBLE

PUMP

LIFTING

ROPE

3-INCH

DISCHARGE

HOSE

POWER

CORD

SUPPORT

PLATFORM

CARRYING

HANDLE

Figure 16. Submersible Pump Upright Position

(Correct)

Figure 17. Submersible Pump Upright Position

(Incorrect)

3. After the pump has been positioned correctly into place,

power can be applied to the pump's electric motor.

SUBMERSIBLE

PUMP

Advertising