Reset button, Activity led (green), Network connectors – Meyer Sound 80 User Manual

Page 31: Resetting the rms module

Advertising
background image

ACHERON OPERATING INSTRUCTIONS

31

Reset Button

Pressing the Reset button causes the RMS module’s firm-
ware to reboot; this will not affect whether the loudspeaker
is commissioned (which is stored in flash memory). You can
simultaneously press the Reset and Service buttons to reset
the RMS module and decommission the loudspeaker from
the network (see “Resetting the RMS Module” on page 31).

Activity LED (Green)

The green Activity LED flashes continuously when the loud-
speaker has been successfully commissioned.

Network Connectors

The two Weidmuller connectors transfer data to and from
the RMS network. Two connectors are provided to allow for
easy connection of multiple (daisy-chained) loudspeakers
on the network. Included with each RMS-equipped loud-
speaker are RMS cable connectors and mounting blocks for
constructing RMS cables. The RMS blocks allow the cables
to be securely attached to the RMS module with screws.

RESETTING THE RMS MODULE

You can use the Reset and Service buttons to reset the RMS
module, which will cause the module to be decommissioned
from the network.

To reset the RMS module:

1. Press and hold the Service button for 10 seconds.

2. While continuing to hold down the Service button, press

and hold the Reset button for 5 seconds.

3. After releasing the Reset button, continue holding down

the Service button for 5 seconds. The RMS module is
reset and the loudspeaker is decommissioned. The RMS
module’s red Service LED blinks.

Advertising
This manual is related to the following products:

100, LF