Wiring Requirements

ATTENTION

Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your EDS-208.
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the
maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.


You should also pay attention to the following items:
y Use separate paths to route wiring for power and devices. If power wiring

and device wiring paths must cross, make sure the wires are perpendicular
at the intersection point.

y NOTE: Do not run signal or communications wiring and power wiring in

the same wire conduit. To avoid interference, wires with different signal
characteristics should be routed separately.

y You can use the type of signal transmitted through a wire to determine

which wires should be kept separate. The rule of thumb is that wiring that
shares similar electrical characteristics can be bundled together.

y Keep input wiring and output wiring separated.
y It is strongly advised that you label wiring to all devices in the system when

necessary.

Grounding EDS-208

Grounding and wire routing help limit the effects
of noise due to electromagnetic interference
(EMI). Run the ground connection from the right
most contact of the 3-contact terminal block to
the grounding surface prior to connecting
devices.

ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface such as a metal panel.