MITSUBISHI ELECTRIC WD-52525 User Manual

Page 23

Advertising
background image

MODEL: WD-52525 / WD-52725 / WD-52825 / WD-62525 / WD-62725 / WD-62825

Page 23

Error Code

Probable Cause

12

No error detected

22

Recovery from momentary Reset

32

Lamp Cover open

33

Air Filter Cover open

34

Lamp abnormality

35

Chassis Fan failure

36

Exhaust (Back Cover) or Lamp Ballast Fan failure

37

Engine (DMD or Lamp) Fan failure

38

Excess Lamp Temperature

39

Excess DMD Temperature

41

Short Detected

44

DVI Cable (between Chassis and Engine) disconnected

ERROR CODES

Press and Hold "DEVICE" and "MENU" FOR 5 SECONDS

3. Error Code Operational Check

Note: The TV must be in “Shut Down” and not manually switched Off, to perform the Error Code Opera-

tional Check. When the TV is switched Off, the code automatically resets to “12” No Error.

Press the front panel “DEVICE” and “MENU” buttons at the same time, and hold for 5 seconds to
activate the Error Code Operational Check. The LED will then flash denoting a two digit Code.

Note: The front panel buttons must be used, NOT those on the Remote Control.

The number of flashes indicates the value of the MSD (tens digit) of the Error Code.

The flashing then pauses for approximately 1/2 second.

The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
Example: If the Error Code is “32”, the LED will flash three times, pause, and then flash two times.

The Error Code is repeated a total of 5 times.

4. Error Codes

The Error Code designations are listed below:

Advertising