(1) Displayed for 0.3 seconds
Focus area LEDs display the active local focus area for 0.3 sec when the
focus is confirmed.

(2) Displayed for 0.6 seconds

Focus area LEDs display the active local focus area for 0.6 sec when the
focus is confirmed.

(3) Not displayed

Active local focus area is not displayed when the focus is confirmed.

• The local focus areas will be displayed for 0.6 seconds when selected with

control dial and the spot AF button (p. 70).

(1) Shutter cannot be released if a lens is not attached.

• [ - - ] appears on the data panel when the shutter button is pressed

partway down.

(2) Shutter can be released if a lens is not attached.

• Use when mounting the camera to a non-coupling lens mount (telescope,

microscope, etc).

Custom 13 - AF Area Display

Custom 14 - Shutter-release Lock (Lens)

CUSTOM FUNCTIONS

Custom 12 - Flash Metering

Your camera uses ADI flash metering as the standard flash metering
mode, but it can be changed.
• This applies to both the built-in and accessory flash.
(1) ADI Flash Metering
When the flash fires, ADI or pre-flash metering will be employed.

• Flash metering changes according to the flash unit and lens being used.

(2) TTL Flash Metering
When the flash fires, TTL metering will be employed.

• To use flash or color meters, flash diffusers, or neutral density filters, the

flash mode must be set to TTL metering

.

(1) AF Illuminator On
The built-in flash is used as an AF illuminator and will fire when
necessary to assist the autofocus system.

• The AF illuminator does not fire when flash cancel is selected.

(2) AF Illuminator Off

The AF illuminator function is canceled. Other flash functions will
operate normally.

• An attached accessory flash’s AF illuminator will not be cancelled.

Custom 11 - AF Illminator (Built-in flash)

(1) Hold to activate
The spot metering area is active until the spot-AE lock button is
released.

(2) Press once to activate, press again to cancel

.

.

The spot metering area is activated when the spot-AE lock button is
pressed and canceled when the button is pressed again.

• When the spot metering area is active, pressing the program-reset button,

turning the camera off, or changing the position of the built-in flash cancels
the metering area.

will appear in the viewfinder when the spot metering area is active.

Custom 10 - Spot-AE Lock Button

This custom function changes the operation of spot-AE lock button.

• When the built-in flash is up or an attached accessory flash is on and the

spot-AE lock button is pressed, slow sync will be activated (p. 96).