Marquis 38, 8clearance to combustibles – Marquis DVR-38 User Manual

Page 8

Advertising
background image

Marquis 38

8

CLEARANCE TO COMBUSTIBLES

CLEARANCES TO COMBUSTIBLES

BACK

0” to stand-offs

SIDES

0” to stand-offs

TOP

0” to stand-offs

BOTTOM

0”

ADJACENT SIDE WALL

1” to side of faceplate

MANTLE

see diagram

VENT

1” to outside side and bottom surface,
2” to outside top surface.

PRECAUTIONS

This appliance must be installed by a qualified gas installer and the installation must
conform to the installation codes.

Provide adequate clearance around air openings of the appliance. Never obstruct front
openings.

Provide adequate clearances for proper operation and servicing of the appliance.

This appliance must be properly connected to a venting system.

Combustible mantle allowed in shaded
area. Mantle extension maybe increased
1” (25mm) for each additional 1” (25mm)
increase in clearance height.

Minimum Height From Top Surround: 6”

Minimum Height From Bottom of Appliance: 37”

NOTE: Low profile wooden crowns and mold-
ings above the unit are not
considered as mantles. I.E. 1” or less protrusions
on the upper mantle facing are acceptable

6” (152 mm)