Control panel, Specifications, Control panel parameter values – Miller Electric 700 User Manual

Page 2: Subject to change without notice.)

Advertising
background image

2

Control Panel

Input
Power

Three-
Phase

Single-
Phase

Three-
Phase

Single-
Phase

Rated
Output

250 A at 30 V,
100% Duty Cycle

300 A at 32 V,
60% Duty Cycle

180 A at 27.2 V,
100% Duty Cycle

225 A at 29 V,
60% Duty Cycle

500 A at 40 V,
100% Duty Cycle

600 A at 44 V,
60% Duty Cycle

360 A at 34 V,
100% Duty Cycle

450 A at 38 V,
60% Duty Cycle

Welding
Amperage
Range

5 – 350 A

5 – 350 A

5 – 700 A

5 – 700 A

Model

Dynasty
350

Dynasty
700

Max.
Open-Circuit
Voltage

75 VDC
10 –15 VDC*

75 VDC
10 –15 VDC*

75 VDC
10 –15 VDC*

75 VDC
10 –15 VDC*

Net
Weight

135.5 lb
(61 kg)

with
TIGRunner

®

308 lb
(140 kg)

198 lb
(90 kg)

with
TIGRunner

®

370 lb
(168 kg)

Specifications

(Subject to change without notice.)

Amps Input at Rated Load Output, 50/60 Hz
208 V 230 V 400 V 460 V 575V

KVA

KW

29

26

15

13

10

10.3

9.9

35

32

18

16

13

12.7

12.1

35

32

15

12

7.4

6.8

47

43

21

17

9.8

9.1

75

68

39

34

27

27

26

97

88

51

44

35

35

34

82

74

37

30

17

16

115

104

52

42

24

22

Dimensions

H: 24-3/4 in (629 mm)
W: 13-3/4 in (349 mm)
D: 22 in (559 mm)

with TIGRunner

®

H: 45-1/8 in (1146 mm)
W: 23-1/8 in (587 mm)
D: 43-3/4 in (1111 mm)

H: 34-5/8 in (879 mm)
W: 13-3/4 in (349 mm)
D: 22 in (559 mm)

with TIGRunner

®

H: 55-1/8 in (1400 mm)
W: 23-1/8 in (587 mm)
D: 43-3/4 in (1111 mm)

Conforms to European standards.

Certified to both the Canadian and U.S. Standards for welding equipment.

*Indicates sense-voltage for Lift-Arc TIG and Low OCV Stick.

1. Memory

36 Combinations
(9 AC TIG)
(9 AC Stick)
(9 DC TIG)
(9 DC Stick)

2. Polarity

AC/DC

3. Process/

TIG: HF Impulse, Lift Arc

Arc Starting

STICK: Adaptive Hot Start

4. Output Control

Standard Remote,
2T Trigger Hold,
Output ON

5. Pulser Control

Pulses per Second DC : 0.1– 5000 PPS

AC : 0.1 – 500 PPS

Peak Time

5 – 95%

Background Amps 5 – 95%

6. Sequencer Control

Initial Amps

Dynasty 350: 5 –350 A
Dynasty 700: 5– 700 A

Initial Slope

0.0 – 50.0 Seconds

Final Slope

0.0 – 50.0 Seconds

Final Amps

Dynasty 350: 5 –350 A
Dynasty 700: 5– 700 A

7. Gas/DIG Preflow 0.0 – 25.0 Seconds

Postflow

Auto Postflow,
Adjust 0.0 – 50 Seconds

DIG

0 – 100%

8. AC Waveshape

EN Amperage

5 – 350 A /5 – 700 A

EP Amperage

5 – 350 A/5 – 700 A

Balance

30 – 99%

AC Frequency

20– 400 Hz

9. Amperage Control

10. Encoder Control

11. Ammeter Display

12. Voltmeter Display

Additional Setup Parameter Values

Programmable Starts
Amperage

5 – 200 A

Time

1– 200 Milliseconds

Polarity EP,

EN

Additional Triggers 3T, 4T, Mini Logic,

4T Momentary

Waveshapes

Advance Squarewave,
Soft Squarewave, Sine
Wave, Triangular wave

Amplitude Lock

EN EP Same,
EN EP Independent

Spot/Weld Timer 0.0 – 999 Seconds

OCV

Low OCV, Normal OCV

Lockouts

Four levels

Arc Timer

0.0 – 9999 Hours
and 0 – 59 Min

Cycle Counter

0 – 999,999 Cycles

Meter Calibration ±0 – 20.0 A mps

±0 – 20.0 Volts

f

13

10

9

11
12

1

2

3

6

4

5

7

8

Control Panel Parameter Values

Advertising