Specifications – MITSUBISHI ELECTRIC DX-ZD6UE User Manual

Page 20

Advertising
background image

20

Specifications

General
Rated Power Supply:

100 to 240 V AC, 50/60 Hz

Rated Input:

0.75 - 0.4 A (100-240 V)

Operating Temperature:

41 °F-104 °F (5 °C to 40 °C)

Relative Humidity:

Max. 80 (%)

Altitude:

Max. 2000 (m)

Dimensions:

424 (Width) x 361 (Depth) x 49 (Height) (mm)

Weight:

6.3 kg (with 2 HDD mounted)

Control terminals
CONT IN

Input terminal linked with the power supply of the recorder

CONT OUT

Output terminal linked with the power supply of the recorder

(CONT OUT is the through output of CONT IN.)

GND (Ground)

For grounding

TEMP ALM

Output terminal for detecting abnormal temperature (open collector output)

Active: “Low” level voltage output, Max. current 7 mA DC.

Non active: Open, Max. voltage 24 V DC.

FAN ALM

Output terminal for detecting fan error (open collector output)

Active: “Low” level voltage output, Max. current 7 mA DC.

Non active: Open, Max. voltage 24 V DC.

HDD ALM

Output terminal for detecting HDD error (open collector output)

Active: “Low” level voltage output, Max. current 7 mA DC.

Non active: Open, Max. voltage 24 V DC.

CONT IN

Reserved.

CONT OUT

Reserved.


EXTERNAL CONTROL:
When set to ON: Power is supplied to the HDD when 12V is applied to the input terminal linked with the power supply.
When set to OFF: Power is always supplied to the HDD.

Serial bus terminal
Serial bus terminal (2 terminals)

(Only DX-ZD6UE is connectable.)

Accessories:

USB2.0 cable

1

Control cable

1

Screws

8

User’s manual (this manual) 1

Power cord

3

Control input/output terminals and circuits

<Interface circuit inside the unit>

Output terminal

GND terminal

TEMP ALM terminal
FAN ALM terminal
HDD ALM terminal

• Output Circuit

Design and specifications are subject to change without notice.

Advertising