Valet/override switch operation – Magnadyne PL30 User Manual

Page 4

Advertising
background image

4

Override Operation: (Security System is Armed)

1. Enter the vehicle. (The security system will begin sounding at this point)
2. Place the ignition key into the ignition switch and turn the ignition switch to the “on” position.
3. Within 5 seconds of turning the ignition key “on”, flip the valet switch to the “on” position.
4. The horn/siren will stop sounding.
5. The LED indicator will be solid red.

The security system is overridden and is now in the valet mode!

Note 1: If the valet switch is already in the “on” position when you turn “on” the ignition key, the override
function will be bypassed. Turn “off” the ignition key, place the valet switch in the “off” position and try again.

Note 2: If you fail to flip the valet switch to the “on” position within 5 seconds of turning “on” the ignition
key, the override function will be locked out. Place the valet switch in the “off” position, turn “off” the
ignition key and try again.

Valet Operation: (The security system is already disarmed)

1. Place the valet switch into the “off” position.
2. Turn the ignition key to the “on” position
3. Place the valet switch to the “on” position.
4a. The LED will be on solid indicating that the security system is in the valet mode. (Ignition key on)
4b. The LED will flash once every 5 seconds indicating the security system in in valet mode. (Ignition key

off)

How to Get Back to Security System Activation Mode:

1. Place the ignition key switch to the “on” position.
2. Place the valet switch to the “off” position.
3. Place the ignition key switch back to the “off” position. You will notice that the LED indicator will be

off. This indicates that you have exited the valet mode and your security system will operate normally.

OFF

OFF

ON

ON

OFF

OFF

ON

ON

Valet Switch in the ON Position

Valet Switch in the OFF Position

Valet/Override Switch Operation: