Magellan All-In-One Security System V1.0 MG-6060 User Manual

Page 16

Advertising
background image

14

Reference & Installation Manual

Follow/Stay Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 004

Follow/Stay zones function as follows:

All zones defined as Follow/Stay zones become Follow
zones (refer to Follow Zones on page 13) when the
Magellan system is Regular armed.

All zones defined as Follow/Stay zones become Stay zones
when the Magellan system is Stay or Instant armed.

Instant Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 005

When an armed Instant zone opens, the console immediately
generates an alarm. Instant zones are commonly used for
windows, patio doors, skylights and other perimeter type zones.

Instant/Stay Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 006

Instant/Stay zones function as follows:

All zones defined as Instant/Stay zones become Instant
zones (refer to Instant Zones on page 14) when the
Magellan system is Regular armed.

All zones defined as Instant/Stay zones become Stay zones
when the Magellan system is Stay or Instant armed.

Standard 24Hr. Fire Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 007

Whenever a Standard 24Hr. Fire Zone opens, whether it is
armed or disarmed, the console will generate the following:

The console can send the corresponding Alarm Report
Code from sections [187] to [190].

Alarms are always audible regardless of other settings. Fire
alarms generate an intermittent (pulsed) bell/siren output
signal as shown in Figure 17 on page 14.

Figure 17: Bell/Siren Output during a Fire Alarm

Delayed Fire Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 008

When a Delayed 24Hr. Fire Zone opens, whether it is armed or
disarmed, the console will react as shown in Figure 18 on page
14. Delayed 24Hr. Fire Zones are commonly used in residential
homes where a smoke detector often generates false alarms (i.e.
burning bread, etc.).

Figure 18: Delayed Fire Zone

24Hr. Burglary Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 009

Whenever a 24Hr. Burglary Zone opens, whether the system is
armed or disarmed, the console will immediately generate an
alarm.

24Hr. Hold-up Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 010

When a 24Hr. Hold-up zone opens, whether it is armed or
disarmed, the console will immediately generate an alarm. The
SIA FSK reporting format includes specific report codes to
identify the alarm as a Hold-up alarm.

24Hr. Buzzer Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 011

This zone definition is particularly useful when a user wishes to
be notified when something such as a safe or locker within the
home has been accessed (i.e. a child accessing a valuable
collection). This zone definition functions as follows:

Whenever a 24Hr. Buzzer Zone opens, whether the console
is armed or disarmed, the console sets off the keypads’
buzzers to indicate that the zone was breached.

The console will report the alarm, but will not enable the bell/
siren output.

Enter any valid access code on the keypad to stop the
buzzer.

Advertising