Specifications, Product dimensions and sensitivity axis – Murphy EVS-A-EX User Manual

Page 2

Advertising
background image

Warranty - A limited warranty on materials and workmanship for one year is given with this FW Murphy product. A copy of the
warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm


Specifications

Environmental

ƒ Operating

Temperature:-40

°F to 185°F (-40°C and +85°C).

ƒ

Humidity: 0-95% non-condensing

ƒ

Vibration: 30 g’s (Mechanical stability)

Power Requirements

Murphy EVS-SB – Internal Battery Power
ƒ

Battery power provided via 7.2V V lithium-Ion cell(s)

ƒ

Open circuit maximum voltage of 10VDC.

ƒ

Batter Life – 1 year under normal operation

ƒ

Normal operation 10v> Vbat> 6.4v

ƒ

Low battery mode: 5.0v< Vbat< 6.4v

ƒ

System shutdown and alarm mode active below 5.0v

Murphy EVS-A, EVS-S – External DC Power
ƒ

External power: 8-32 VDC

ƒ

Input Current: 100mA Max

Product Accuracy

ƒ

±5% of full scale at 1.5 ips and 21 deg C.

ƒ

±5% Variation over temperature from 21 deg C, over
operating range..

ƒ

Integration Stage End-to-End Noise: <0.01 ips RMS

Murphy EVS-S and EVS-A
ƒ

±5%, at Bandwidth of 6 to 500 Hz from 50Hz calibration
point

ƒ

±3dB at Bandwidth of 3 to 875 Hz, worst case

Murphy EVS-SB
ƒ

±5%, at Bandwidth of 6 to 350 Hz from 50Hz calibration
point

ƒ

±3dB at Bandwidth of 3 to 875 Hz, worst case

Trigger Feature

ƒ

Trigger level between 0.1 and 1.5 inches per second (ips)
Peak

ƒ

Trigger set with single turn adjustable PC board mount
potentiometer

ƒ

PC board marked with 15 marks corresponding to 0.1 to 1.5
in 0.1 increments

Time Delay Feature

ƒ

Adjustable from 0 to 10 seconds

ƒ

Set with adjustable single turn PC board mount
potentiometer

ƒ

PC board marked with 11 marks corresponding to 0 to 10
seconds in 1 second intervals

Output

ƒ

Normally-Open and Normally-Closed outputs simultaneously
available

ƒ

Open-collector outputs sink to Common Ground

ƒ

50 mA sink capacity

ƒ

Input voltage: 40 VDC maximum

ƒ

Switch output is selectable for latched or non-latch
configurations. Reset accomplished by reset pushbutton or
external contact closure when in latch mode.

ƒ

Shutdown Alarm activated on power loss

LED Outputs

Alarm LED output
ƒ

Red LED

ƒ

LED strobing for first 5 minutes after entering Alarm mode

ƒ

Flashing thereafter until Reset activated

ƒ

Strobe rate: 2mSec on, every 0.5

±0.25 seconds

ƒ

Flash rate: 2mSec on, every 6

±1 seconds

Power LED output
ƒ Green

LED

ƒ

Flash Duration: 2mSec

Murphy EVS-S and EVS-A
ƒ

Flash once every 6

±1 seconds

Murphy EVS-SB
ƒ

Battery status “Normal”: Flash once every 6

±1 seconds

Battery in “Low-Battery” range: Flash once every 12

±1

seconds

4-20mA output (EVS-A only)

ƒ

Power obtained from power supply

ƒ

Loop Resistance: 600 ohms max at 24 V and 20mA.

ƒ

Current loop accuracy

±5% from internal setpoint

ƒ

20 ma corresponds to 1.5 ips Peak

ƒ

4 ma corresponds to 0 ips Peak

Reset

ƒ

Local reset switch w/momentary contact

ƒ

External reset: Available via header and will require an
external relay or pushbutton contact to ground to activate the
reset.

ƒ

Activation Period: Reset must be active for 0.5 sec.
minimum to reset the switch.

Circuit Functional blocks

ƒ

Charge Amp interface
- The input Transducer is an integrated PZT element for
measuring acceleration with an internal charge converter.
- Maximum G level of 13 g’s at 500hz

ƒ Bandpass

Filter

- Frequency response dependent on model number (refer to
“Product Accuracy”)

ƒ Integration

- Integration to convert from G to IPS peak

Approvals

ƒ

Hazardous Area approvals applied for. (refer to “Product
Table”)

NMEA

4

Product Dimensions and Sensitivity Axis

Advertising
This manual is related to the following products: