MaxTech xpm56i V.34+ User Manual

Page 13

Advertising
background image

11

%E_

%E0

Disable auto-retrain

%E1

Enable auto-retrain

+MS?

Displays the current Select Modulation
settings

+MS=?

Displays a list of supported Select
Modulation options

+MS=a,b,c,d.e,f Select modulation where: a=0, 1, 2, 3,

9, 10, 11, 56, 64, 69; b=0-1; c=300-
56000; d=300-56000; e=0-1; and f=0-
1. A, b, c, d, e, f default=56, 1, 300,
56000, 0, 0.
Parameter “a” specifies the
modulation protocol desired where:
0=V.21, 1=V.22, 2=V.22bis, 3=V.23,
9=V.32, 10=V.32bis, 11=V.34,
56=K56FLEX, 64=Bell 103, and 69=Bell
212. Parameter “b” specifies automode
operations where: 0=automode
disabled, 1= automode enabled with
V.8/V.32 Annex A. Parameter “c
specifies the minimum connection data
rate (300-56000). Parameter “ d
specifies the maximum connection rate
(300-56000); Parameter “e” specifies
the codec type (0=µ-Law, and 1=A-
Law). Parameter “f” specifies “robbed
bit” signaling detection (0=detection
disabled 1=detection enabled)

#CID=n n=0

Disable Caller ID

n=1

Enables Caller ID with formatting (date,
time, number, name)

n=2

Enables Caller ID without formatting

#CID?

Displays current Caller ID mode

#CID=?

Returns Caller ID capabilities of modem.

3.5 MNP/V.42/V.42bis Commands

%C_

%C0 Disable MNP Class 5 and V.42bis data

compression

%C1 Enable MNP Class 5 data compression

only

%C2 Enable V.42bis data compression only
%C3 Enable MNP Class 5 and V.42bis data

compression

Advertising