6.

Is Data Transfer Failing?
YES

Verify the local copper connection by starting a local copper loop-
back (set the loop-back switch on the local media converter to “CL”)
and then use a bit error test unit at the local location to run a bit error
test.

Verify the local fiber connection by starting a local fiber loop-back at
the remote location
(set the loop-back switch on the remote media
converter to “FL”) and then use a bit error test unit at the local
location
to run a bit error test.

Verify the remote copper connection by starting a local copper loop-
back at the remote location (set the loop-back switch on the remote
media converter to “CL”) and then use a bit error test unit at the
remote location
to run a bit error test.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

Proceed to step 7.

[email protected] -- Click the “Transition Now” link for a live Web chat.

11

Declaration of Conformity

Name of Mfg:

Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

CCSCF30xx-10x Series Media Converter

Part Number:

CCSCF3011-100, CCSCF3013-100, CCSCF3014-100,
CCSCF3015-100, CCSCF3016-100, CCSCF3017-100,
CCSCF3018-100, CCSCF3019-100, CCSCF3029-100,
CCSCF3029-101, CCSCF3029-102, CCSCF3029-103,
CCSCF3039-100

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the CCSCF30xx-10x to which this declaration refers is

in conformity with the following standards.

CISPR 22:1993; EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 Subpart B;

61000-3-2:1995+A14:2000; 61000-3-3:1995; CFR 21 subpart J

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

September 19, 2005

Stephen Anderson, Vice-President of Engineering

Date

7.

Is the SDC (Signal Detect / Coax) LED illuminated yellow?
YES

A failure of the remote unit connected to the coax interface has
caused an Alarm Indication Signal (AIS) on the coax interface.
Correct the remote unit failure.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

Proceed to step 8.

8.

Is the SDF (Signal Detect / Fiber) LED illuminated yellow?
YES

A broken coax link has caused an Alarm Indication Signal (AIS) on
the fiber interface. Correct the coax link failure.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

Fiber

Coax

Coax

Original Fault

AIS on the coax link

Fiber

Coax

Coax

Original

Fault

AIS on the fiber link