MITSUBISHI ELECTRIC PE-15MYC User Manual

Page 55

Advertising
background image

- 54 -

OUTDOOR

INDOOR UNIT

OUTDOOR UNIT

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.

6.Specification subject to change without notice.

Timer (Anti short cycle.)

TM

Contactor (fan O/D)

52F2

Timer

2

Over current relay(fanO/D)

51F2

Auxiliary relay (fan)

30FZ

Surge killer

CR1~3

C1, 3, 8

Connector

Internal thermostat(compressor)

49C1,2

Compressor motor

Symbol

Terminal block

Over current relay(compressor)

Fan motor (outdoor)
Contactor (compressor)

Over current relay(fanI/D)

Contactor (fan I/D)

Crankcase heater

Transformer

Fuse (3.15A)

Fan motor (indoor)

TB1~4

MC1,2
MF1
MF2
52C1,2

51F1

CH1,2

Tr

51C1,2

F1~3

Name

63H1,2

High-pressure switch

52F1

FZ

Auxiliary relay (fan)

Auxiliary relay
Auxiliary relay (check)
Switch (on)

CZ1-1,2/2-1,2
30CZ1,2
<SW1>
<23WA>

Thermostat (room temp.)

C1

52

TM

(3min)

TM

(3min)

52
C2

TM

CZ2-2

CZ2-1

C1

C2

52

52

Caution,
1.To protect each Fan motor and Compressor from abnormal current,
Over current relays<51C1,2>,<51F1,2,3>are installed. Therefore,
do not change factory set value of Over current relays.
2.To protect the starting Compressor<MC1,2>at the same time, Timer
<2> is installed. Therefore, do not change factory set value of this Timer.
3.To protect the starting Compressor<52C1,2>frequently, Timer
<TM> is installed. Therefore, do not change factory set value of this Time

24VAC(N)

FAN HI

COMP2

COMP1

24VAC(L)

PAC-204RC (Option)
terminal no.

2
3

Cooling operation

52

F1

F2

52

52
C1

C2

52

52F2

63H1

63H2

51C2

51C1

2(2sec)

2

CZ

1-2

CZ

1-1

CZ2

30

C2

52

52
C2

WA

23

CR3

CR2

CR1

1

GRAY

GRAY

GRAY

30

CZ1

30

CZ2-1

52

C1

CZ1

12

11

13

52F1

1-2

CZ

1-1

CZ

TB3

12

11

12

11

13

TB3

2-2

CZ

CZ

2-1

13

5

FZ

3

TB3

2

4

SWITCH BOX (FIELD SUPPLY)

23
WA

SW1

F2

(3.15A)

AC
24V

Tr

AC

220~

240V

TB4

2-2

CZ

CZ

2-1

CH2

52
C1

CH1

51

49C1

F2

30
FZ

FZ

30

FZ

CZ2-2

CZ2

30

49C2

F3(3.15A)

BLACK

WHITE

RED

51C2

52C2

MC2

BLACK

WHITE

RED

BLACK

WHITE

Power (Neutral)

Fan operation

Cooling operation

Power (Active)

Function

5

4

1

No.

TB3

Symbol

Option controller connection.

PE

PE

PE-15MYC-EU ··· 30A

PU-15MYC1-EU ··· 100A

C1

MC1

F1

(3.15A)

52C1

CIRCUIT BREAKER
(FIELD SUPPLY)

BLUE

BLUE

BLACK

WHITE

RED

TB2

L1

L2

L3

N

CIRCUIT BREAKER
(FIELD SUPPLY)

51C1

3

2

1

51F2

WHITE

51F1

MF1

52F1

MF2

RED

RED

WHITE

BLACK

BLACK

BLACK

WHITE

BLACK

WHITE

RED

RED

RED

TB1

L1

L2

L3

N

Power supply, 3 Phase
380~415 Volt, 50Hertz

Power supply, 3 Phase
380~415 Volt, 50Hertz

5.When PAC-204RC is used, Timer(TM)is unneccessary.

Thermostat (freeze protection)

26L1,2

3

1

C3

C3

51F1

26L1

3

1

C8

C8

26L2

PE-15MYC-EU

(SPECIAL ORDER : ANTI SHORT CYCLE TIMER)