11. overload protection – Miller Electric XR Control User Manual

Page 45

Advertising
background image

OM-1594 Page 39

7-11. Overload Protection

Ref. 801 577 / Ref. 800 185-A

Y Turn Off wire feeder and

welding power source. Stop

engine on welding

generator.

If fuse opens, unit shuts down. To

replace fuse, proceed as follows:
1

Fuse Holder Cover

2

Fuse F1 (See Parts List)

3

Circuit Breaker CB1

If CB1 opens, the gun drive motor,

gas valve, and contactor will not

operate when trigger is pulled. The

gun drive motor operates in the Jog

mode with CB1 open.
Check for blocked gun liner.
Check for jammed wire, binding

drive gear or misaligned drive rolls

in feeder. Correct problem.
Allow cooling period and manually

reset breaker. Close and latch door.

3

1

2

7-12. Water Flow Switch (Optional For Water-Cooled Models)

The water flow switch protects the gun from overheating. If coolant flow rate drops below 1 qt/min, the water flow

switch opens and stops the welding wire from feeding. See Section 7-13 for remedies to this trouble.