OM-1318 Page 13

3-4.

Electrical Service Guide

Input Voltage

230

Input Amperes At Rated Output

20

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Circuit Breaker

1

, Time-Delay

2

20

Normal Operating

3

30

Min Input Conductor Size In AWG/Kcmil

14

Max Recommended Input Conductor Length In Feet (Meters)

66

(20)

Min Grounding Conductor Size In AWG/Kcmil

14

Reference: 1999 National Electrical Code (NEC)

1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.

2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).

Y

Caution: Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard.

3-5.

Selecting A Location And Connecting Input Power

1

Rating Label

Supply correct input power.

2

Plug

3

Receptacle

Connect plug to receptacle.

4

Line Disconnect Device

See Section 3-4.

Y

Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.

ssb2.2* 1/94 – ST-801 988 / 802 401

1

18 in (457 mm) of
space for airflow

L1

L2

L1

L2

2

230 VAC, 1

Y

Always connect
grounding
conductor first.

= GND/PE

4

3

Y

Do not move or operate unit
where it could tip.