Troubleshooting table, 4. troubleshooting table – Miller Electric OM-2241 User Manual

Page 23

Advertising
background image

OM-2241 Page 19

5-4.

Troubleshooting Table

Trouble

Remedy

No weld output; unit completely
inoperative.

Place line disconnect switch in On position (see Section 3-13).

Check fuse F1, and replace if necessary (see Section 5-2).

Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 3-13).

Check for proper input power connections (see Section 3-13).

Check for proper jumper link position (see Section 3-13).

No weld output; Power switch pilot light
on; fan on.

Check, repair, or replace feeder (see wire feeder Owner’s Manual).

Unit overheated. Allow unit to cool with fan On (see Section 3-2).

Have Factory Authorized Service Agent check control board PC1.

Unit provides only maximum or mini-
mum weld output.

Have Factory Authorized Service Agent check control board PC1.

Erratic or improper weld output.

Use proper size and type of weld cable (see Section 3-8).

Clean and tighten all weld connections.

Check wire feeder installation according to Owner’s Manual.

Have Factory Authorized Service Agent check control board PC1 and/or SCR in main rectifier.

No 115 volts ac output at duplex
receptacle or Remote 14 receptacle.

Reset circuit breaker CB1 (see Section 3-7).

No 24 volts ac output at Remote 14 re-
ceptacle.

Reset circuit breaker CB2 (see Section 3-7).

Fan not operating.

Check for and remove anything blocking fan movement.

Have Factory Authorized Service Agent check fan motor.