Specifications – Meyer Sound CQ-2 User Manual

Page 16

Advertising
background image

16

Complementary power MOSFET output stages class AB/H

1240 Watts (620 Watts/channel)

< .02 %

Acoustical

Copyright © 1997 Meyer Sound Laboratories, Inc.

All rights reserved

Part # 05.041.010.01 Rev A

±

4 dB 40 Hz – 18 kHz

±

90

°

50 Hz – 16 kHz

CQ-1: 136 dB ; CQ-2: 139 dB

> 110 dB

Specifications

Frequency Response

1

Phase Response

1

Maximum Peak SPL

1

Dynamic Range

2

Coverage

CQ-1

–6 dB points

–10 dB points

–6 dB points

–10 dB points

CQ-2

CQ-1

CQ-2

Acoustical Crossover Point

Transducers

Low Frequency

High Frequency

Audio Input

Type

Connector

Nominal Input Level

Amplifiers

Type

Burst Capability

3

THD, IM, TIM

AC Power

Connector

Automatic voltage selection

4

Max Continuous RMS Current (> 10 s)

Max Burst RMS Current (< 1 s)

Max Peak Current During Burst

Soft Current Turn-on

Physical

Dimensions

Weight

Enclosure/Finish

Protective Grill

Rigging

10 k

impedance, electronically balanced

XLR (A-3) male and female

+4 dBu (1.23 Vrms)

H: 50

°

(800 Hz – 12 kHz); V: 40

°

(1.5 kHz – 12 kHz)

H: 60

°

(800 Hz – 12 kHz); V: 50

°

(1.5 kHz – 12 kHz)

15” diameter MS-15 cone

4” diaphragm MS-2001CQ horn compression driver

250 V NEMA L6-20P / IEC 309 Twistlock male receptacle

85 – 134 V / 165 – 264 V; 50 Hz / 60 Hz

115 V: 8 A 230 V: 4 A

100 V: 10 A

115 V: 15 A 230 V: 8 A

100 V: 18 A

115 V: 22 Apk 230 V: 11 Apk

100 V: 25 Apk

Inrush current < 12A @115V

21” W x 30” H x 22

1

2

” D

130 lb (59 kg); shipping: 150 lb (68 kg)

All birch plywood/black textured

Perforated steel grill, charcoal-grey foam
Four aircraft pan fittings (two on top and bottom).
Working load for each fitting is 500 lb (

1

5

the cabinet

breaking strength) with straight tensile pull.

H: 80

°

(500 Hz – 16 kHz); V: 40

°

(1.5 kHz – 12 kHz)

H:100

°

(500 Hz – 16 kHz); V: 50

°

(1.5 kHz – 12 kHz)

700 Hz

900 Hz

Notes

1.

Subject to half-space loading; measured
with one-third octave frequency resolution
in fixed ISO bands.

2.

Measured as the ratio between the peak
SPL and the A-weighted noise floor.

3.

Nominal 8

resistive load, pink noise,

100 V peak.

4.

The unit is rated at 88 – 125 VAC and
182 – 235 VAC, 50/60 Hz, to satisfy EC
standards for –10% to 6% AC line voltage.

Advertising