Maxon Telecom MPB3328CNE User Manual

Page 2

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

2

TABLE OF CONTENTS

Packaging .........................................Page 2

Introduction ......................................Page 2

General Information ..........................Page 2

Location ............................................Page 4

Appliance Clearances ........................Page 4

Fireplace Specifi cations .....................Page 5

Gas Vent Rule ...................................Page 5

Framing Specifi cations ......................Page 6

Typical Installation Sequence ............Page 6

Installing The Fireplace .....................Page 7

Vent System Installation ...................Page 8

Field Wiring .......................................Page 8

Connecting Gas Line .........................Page 10

Outside Air Kit Installation .................Page 10

Installing Logs .................................Page 11

Appliance Operation ..........................Page 16

Millivolt Appliance Checkout .............Page 16

Electronic Appliance Checkout ..........Page 16

Installing Glass Door .........................Page 16

Burner Adjustments ..........................Page 17

Spillage Test ......................................Page 17

Manual Limit Switch .........................Page 17

Hood Installation ...............................Page 17

Finishing Requirements ....................Page 18

Cold Climate Insulation .....................Page 18

Installation Accessories ....................Page 18

Gas Conversion Kits .................. Page 19

This installation manual will help you obtain a
safe, effi cient, dependable installation for your
appliance and vent system.

Please read and understand these

instructions before beginning your

installation.

PACKAGING LIST

The assembled vented gas fi replace is pack-
aged with:
1 - One log set located in fi rebox area.
2 - One envelope containing the literature

package which consists of the homeowner's
manual, installation instructions, log set
supplement and warranty; envelope is
located in the control area.

3 - One hood located behind the top panel.
4 - One bag of decorative volcanic stone located

in the control area.

5 - One bag of glowing embers (rockwool)

located in the control area.

INTRODUCTION

These vented gas fi replaces are designed to
operate on either natrural or propane gas. They
must be installed with approved type-B, double
wall vent pipe systems routed to the outside
atmosphere.

The Millivolt appliances have a millivolt gas
control valve with piezo ignition system provides
safe, effi cient operation. If any optional acces-
sories which require electrical power are being
installed, the electrical power must be provided
at the time of appliance installation.

The Electronic appliances have an electronic
intermittent pilot ignition system provides safe,
effi cient operation. External electrical power is
required to operate these units.

These appliances comply with National Safety
Standards and are tested and listed by OMNI-
Test Laboratories, Inc. (Report No. 116-F-36-5)
to ANSI Z21.50 (in Canada, CSA 2.22), and
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fi replaces.

Misc. Codes / Standards -
The Installation must conform to local codes or,
in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest
edition, or the Natural Gas and Propane Instal-
lation Code, CSA B149.1 - latest edition.

The appliance, when installed, must be electri-
cally grounded in accordance with local codes or,
in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 - latest edition,
or the Canadian Electrical Code, CSA C22.1
- latest edition.

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE
OR ITS COMPONENTS. ANY MODIFICA-
TION OR ALTERATION MAY VOID THE
WARRANTY, CERTIFICATION AND LIST-
INGS OF THIS UNIT.

Massachusetts -
Installation of these fi replaces are approved for
installation in the US state of Massachusetts if the
following additional requirements are met -

• Installation and repair must be done by a

plumber or gas fi tter licensed in the Com-
monwealth of Massachusetts.

• The fl exible gas line connector used shall not

exceed 36 inches (92 centimeters) in length.

• The individual manual shut-off must be a

T-handle type valve.

New York City, New York -
Installation of these fi replaces are approved for
installation in New York City in the US state of
New York (approval no. MEA 417-05-E), if the
following additional requirements are met -

• An outside air kit (FOAK-4 or FOAK-4LD)

must be installed. See Figure 1a and Page
18
for ordering information.

GENERAL INFORMATION

Note: Installation and repair should be per-
formed by a qualifi ed service person. The
appliance should be inspected annually by a
qualifi ed professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc.

It is imperative that the control compartment,
burners and circulating air passageways of the
appliance be kept clean.

S'assurer que le brùleur et le compartiment des
commandes sont propres. Voir les instructions
d'installation et d'utilisation qui accompagnent
l'apareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.

Figure 1a

WARNING

Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage. Refer to this manual. For
assistance or additional information
consult a qualifi ed installer, service
agency or the gas supplier.

Vertical
Venting

Shown with Outside Air Kit

installed (model FOAK-4 or

FOAK-4LD)

NEW YORK CITY, NY AND MASSA-
CHUSETTS REQUIREMENTS

These appliances are approved for installation
in the following USA locations listed in the
following:

Advertising