4. Venting and setting the dosage on
“DOS module G 60 or C 60” (special
version)

Set the dosage selector on the DOS
module to the “10” position (on DOS
module C 60 only).

Turn the programme selector to the
f “STOP” position.

Switch off the machine.

Press 4 and

6 at the same time,

hold them in and whilst doing so
switch the machine on with the

I-0

button.
The current programme status “P...”
appears in the display.
The

p / 6 indicator light comes on.

Press 3 twice, “E02” (programming
level 2) appears in the display.

Venting the dispensing system:

Turn the programme selector to the
p position. “do1” appears in the dis-
play.

Press 4 for 90 seconds.
The dispensing system is vented.

If only venting is required:

Switch the machine off with the

I-0

button.

Immediately after this: start the D
(COLD) programme, so that after vent-
ing any agents in the wash cabinet are
diluted before being drained away.

Setting the dosage:

Set the amount to dispense according
to the detergent manufacturer’s recom-
mendations.
The machine needs 7 litres of water in
the “Main wash” programme stage.

Example:
The detergent manufacturer recom-
mends 4 ml cleaning agent per litre of
water.
7 l x 4 ml/l = 28 ml.
2 ml

. 1 sec. dispensing time; i.e. pro-

gramming to 14 secs.

Turn the programme selector to the

q

position, the dispensing time in

seconds appears in the display, e.g
“10”.

Press 4 repeatedly or hold it in,
until the number “14” appears in the
display (dispensing time 14 seconds
. 28 ml - see example).
The dispensing time/amount is set.

Having changed a value or all
values:

Press

6. “SP” appears in the display.

Press

6 again. The change has

been recorded.

Value set:

If the dispensing system also needs to
be vented:

Start the D (DRAIN) programme, so
that after venting any agents in the
wash cabinet are diluted before
being drained away.