SECTION 2

INSTALLATION

21

To Gas Supply Pipe

Full Flow Gas
Shutoff Valve

Flexible Hose

Union

90-deg.
ST. Elbow

Appliance
Connection
(Male Nipple)

The

minimum gas line pressure at the input side of the

full-flow gas shutoff valve, when the oven burner is
operating on the high flame, MUST be, for natural gas,
6

″ w.c. (14.9mbar), 1.13 kPa and for propane gas,

11

″ w.c. (27.4mbar) 2.75 kPa. Sufficient pressure must

be available to provide for the maximum BTU consump-
tion rate for the oven: 116.0 mJ/h, 110,000 BTU/hour for
each PS540 Oven. For double oven installations, the
BTU/hour requirement for a single oven is doubled. For
triple oven installations, the BTU/hour requirement for
a single oven is tripled.

VI. CONVEYOR REAR STOP AND END

STOP INSTALLATION

Locate the conveyor rear stop and end stop in the
installation kit. Install the rear stop and end stop at the exit
end of the oven. See Figure 2-14.

Figure 2-13. Flexible Hose Installation

Middleby

Marshall

Conveyor Rear Stop

Conveyor End Stop

Figure 2-14. Installing Rear and End Stops