Marmitek PROGUARD800 Series RP835 User Manual

Page 3

Advertising
background image

3 © MARMITEK

INSTALLATION

1. Register all wireless devices to the ProGuard800 control panel as explained in

the ProGuard800 installation manual.

2. On the control panel, define the detection devices that are intended to transmit

via the repeater as follows:

• From the Programming menu, select Devices, Zones [911].
• Select the zone you want to program (1-32).
• From the zone’s sub-menu, select Repeater [#9].
• Select “Use Repeater”.
Note: It is not necessary to define, at the control panel, the keypads and
keyfobs that are registered to the repeater.

3. Open the RP835’s plastic housing. To do so, remove the two cover screws

and lift the front cover away from the base.




















4. Connect the antenna provided to the antenna connector.

5. Connect the backup battery pack to the Battery connector.

6. Connect a 9VAC or 12VDC transformer to the Power Input terminal block

(polarity is not important).

7. All registration and test functions, described in the following sections, are

performed from the LCD Programming Keypad (PK836) shown in Figure 3.

Antenna

Connector

Programming
Keypad (PK836)

Lower

Mounting

Hole

Lower
Mounting
Hole

LED Indicator

Receiver

Tamper
Switch

AC Power

Protection Fuse

Upper

Mounting

Hole

Transmitter

Flash
Programming

Power Input

Terminals

Wiring

Hole

Backup
Battery Pack

Battery Connector

Figure 2: RP835 (cover removed)

Advertising
This manual is related to the following products: