MODELS: WS-48513 / WS-48613 / WS-55513 / WS-55613 / WS-55813 / WS-65513 / WS-65613 / WS-65713 /

WS-65813 / WS-73513 / WS-73713

-----

-----

------

------

Monoscope

Video Input

[Video Circuit]

7. Black Level

To set the black level of the picture.
Excess or insufficient brightness.

1. Supply a Monoscope signal to a Video Input.
2. Activate the Adjust Mode, VC Function.
3. Adjust Item “2 SBRT” so the 0% and 10% black levels on the gradation scale

are the same.

4. Press ENTER to save data.
7. Exit the Service Mode.

40% 30% 20% 10%

50% 0%

0%

0%

60% 70% 80% 90%

GRADATION SCALE

DC ma meter

DT connector pins 7 & 8

------

-----

Grayscale

RF Input

To set overall beam current to its’ optimum level.

Excess or insufficient contrast.

Note: Activate the Expand mode (full screen).

1. Supply a Grayscale signal to a RF Input.
2. Activate the Adjust Mode, VC Function.
3. Select Item “1 SCT”, signal level automatically reduces.
4. Connect a 3ma DC meter between DT connector pins 7 and 8. Positive lead to

pin 7.

5. Adjust Item “1 SCT” to the values given in the Table below.

6. Remove the meter.
7. Save data and Exit the Service Mode.

[Video Circuit]

8. Sub Contrast

CIRCUIT ADJUST MODE

Activate …….. MENU-0-3-5-7
Function …...………..AUDIO
Item No. ……….…….VIDEO
Adjus t Data ….…….ADJUST
Save Data …. ………ENTER
Exit …………..MENU (twice)

CIRCUIT ADJUST MODE

Activate …….. MENU-0-3-5-7
Function …...………..AUDIO
Item No. ……….…….VIDEO
Adjus t Data ….…….ADJUST
Save Data …. ………ENTER
Exit …………..MENU (twice)

MODEL

CURRENT

48 inch models

525 ±5ua

55 inch and 65 inch models

575 ±5ua

73 inch models

575 ±5ua