ceptacle RC2 with respect to circuit common to start the

motor and 0 volts dc should be present when the gun

trigger is released to stop the motor. If +24 volts dc are

not present at pin A when the gun trigger is pressed, re-

place Spot/Burnback Board PC2.

D. Contactor Control Circuit

When the gun trigger is pressed and +19 volts dc are

present at pin D of receptacle RCl with respect to DC

Spot Time

DIP Switch

Si

circuit common, a contactor control output voltage of

+24 volts dc should be present at pin B of receptacle

RC2 with respect to circuit common. When the gun trig-

ger is released, 0 volts dc should be present at pin B af-

ter a delay of 0 to 0.25 seconds depending on the time

set on Burnback Potentiometer R26. If +24 volts dc are
not present at pin B when the gun trigger is pressed or 0

volts dc are not present when the gun trigger is released,

replace Spot/Burnback Board P02.

SA-125 969-C

Figure

8-2. Optional SpotlBurnback Board PC2 Component Locations And Information

S-2iE

TM-1571 Page 21