Trouble

Remedy

Engine does not go to low (idle) speed
with Engine Speed switch in Run/Idle
position.

Be sure Engine Speed switch is in Run/Idle position.

Remove all weld and generator power loads.

Turn off remote device connected to Remote 14 receptacle RC1 (see Section 4-8).

Check for obstructed movement of throttle solenoid linkage.

Have Factory Authorized Service Agent check timer module and current transformer CT1.

Reset circuit breaker CB9 (see Section 7-9).

Engine does not go to high (run) speed
when generator power or large weld
load is applied with Engine Speed
switch in Run/Idle position.

Place Engine Speed switch in the Run position. Have Factory Authorized Service Agent check unit.

Engine uses oil during run-in period;
wetstacking occurs.

Dry engine (see Section 9 and engine manual).

Coolant recovery tank continuously
overflows.

Bleed air from radiator, and replace lost coolant (see Section 4-3).