All dimensions in inches and millimeters – MedCenter HORN DB3 User Manual

Page 3

Advertising
background image

© MEDC 2001

06/01

GENERAL ARRANGEMENT

All cable glands should be of an equivalent NEMA/IP rating to that of the unit

and integrated with the unit such that this rating is maintained.

Once termination is complete, carefully push the cover back onto the unit, avoid-

ing damage to the mating surfaces. Tighten the 6 off cover screws evenly, to

ensure maintenance of the required gap between the cover and enclosure.

3. OPERATION

The unit is initiated directly from the power source.

For all versions, a 5-way DIL switch selects the tone required from the list shown.

The DB3P includes two 5-way DIL switches to select any two tones from the list.

These units can be switched between any two of the tones listed by either:-

· Reversing the polarity of the power supply, or

· By a 3 wire common +ve system, switching between the two –ve lines.

10

11

/

16

"

271mm

Ø 4

5

/

8

" / 117mm

Ø 6

11

/

16

" / 170mm

FIXING HOLE Ø

1

/

2

" / 13mm

FIXING HOLES

Ø ALL

11

/

32

" / 9mm (2 POS.)

2 x

1

/

2

" NPT ENTRIES MAX

7

19

/

32

"

193mm

1

3

/

16

"

30mm

1

3

/

16

"

30mm

POSITION 2 IS USED IF ONLY 1 x

1

/

2

" NPT ENTRY REQUIRED

2

3

/

32

"

53mm

ALL DIMENSIONS IN INCHES AND MILLIMETERS

Advertising