4. rear panel connections, 5. 14-pin plug information – Miller Electric D-64 User Manual
Page 17
OM-1582 Page 13
Ref. 800 353-B
Tools Needed:
4-4.
Rear Panel Connections
1
”Y” Adapter Gas Hose
(Supplied)
2
Shielding Gas Valve Fitting
Requires fitting with 5/8-18 right-
hand threads.
3
Weld Cable Terminal
4
Jumper Weld Cable
5
Weld Cable
6
Optional Current Sensor
Connections
7
14-Pin Cord
8
Power Switch
9
Rating Label Location
9/16, 5/8 in
3/16 in
1
2
3
4
5
4
5
6
7
8
9
6
4-5.
14-Pin Plug Information
Pin*
Pin Information
A
24 volts ac with respect to socket G.
B
Contact closure to A completes 24 volts ac contactor control circuit.
A
J
G
Circuit common for 24 volts AC circuit.
A
J
B
K
I
C
+10 volts dc output to remote control with respect to socket D.
C
L
N
H
D
M
G
D
Remote control circuit common.
D
M
G
E
F
E
0 to +10 volts dc input command signal from remote control with respect to socket D.
H
Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.