Video troubleshooting table, continued – Midway UPRIGHT DEDICATED VIDEO GAME 25" CABINE 16-20044-101 User Manual

Page 100

Advertising
background image

Troubleshooting

6-13

Video Troubleshooting Table, continued

SYMPTOM

CAUSE

REQUIRED ACTION

Floppy disk in drive

Check floppy drive for diskette. If you find disk,
eject it. Leave VGM power on. Turn off
computer. Wait for hard disk to stop spinning.
Turn on computer.

Faulty wiring

Loosen computer case lid thumbscrews and lift
off cover. Assure that hard drive ribbon cable
connector is fully seated into mating connector
on motherboard. Check hard drive power cable.

Improper components

1. Verify that hard disk drive is correct for this

VGM. Label on drive records manufacturer
name, assembly number and program version.

2. Verify that circuit boards are correct for this

VGM. Label on each board records
manufacturer name, assembly number and
hardware version.

3. Verify that ROM instruction set is correct for this

VGM. VGM set includes more than one ROM.
Label on each ROM records assembly number
and software version.

VGM (video game machine)
doesn’t appear

No audio

Power-up self-test runs

Hard drive problems

1. Turn computer on. Immediately look under hard

drive. Hard Drive Activity LED flashes if drive is
operating properly.

2. Allow VGM to load normally. Note and record

any error messages that occur during self-test.

3. Remove hard drive and install it in working VGM.

If symptom recurs there, hard drive is faulty.
Replace it.

Blotches of color appear on
screen

Picture tube aperture
mask is magnetized

Remove diskettes from room. Demagnetize
monitor with external degaussing coil. Take care
not to magnetize neighboring VGMs. Monitor
may be on or off for this procedure.

White areas in center of
screen appear tinged with
color

Object edges have fringe of
one or more colors

Picture tube purity or
static convergence is
out of alignment

1. Turn on VGM.
2. Press and hold TEST MODE to enter Menu

System. At Operator (Main) Menu, select
Diagnostic Menu. Then select Monitor Patterns
Menu. Run through Crosshatch, Red, Green and
Blue screens to find clearest display of problem.

3. Display screen with greatest problem.
4. Display Crosshatch Screen. Locate purity and

static convergence ring magnets on back of
monitor neck. Watch screen in mirror. Adjust
magnets to minimize problem. Follow
instructions from monitor manufacturer.

5. Display Crosshatch Screen. Touch up

adjustments while watching screen in mirror.

CAUTION: Don’t operate the monitor without its Remote Adjustment Board.

WARNING: HANDLE FLUORESCENT TUBE AND CRT WITH CARE. If you drop a
fluorescent tube or CRT and it breaks, it will implode! Shattered glass can fly eight feet
or more from the implosion.