OM-4421 Page 17

SECTION 5 − INSTALLATION

install3 8/06 − Ref. 800 652 / Ref. 800 477-A / 803 274 / 804 712

Y Always securely fasten weld-

ing generator onto transport

vehicle or trailer and comply

with all DOT and other applica-

ble codes.

Y Always ground generator

frame to vehicle frame to pre-

vent electric shock and static

electricity hazards.

Y If unit does not have GFCI re-

ceptacles, use GFCI-protected

extension cord.

Y Do not install unit where air

flow is restricted or engine

may overheat.

.

See Section 4-2 for lifting eye rat-
ing.

.

See Section 5-3 for mounting in-
formation.

Grounding:
1

Equipment Grounding Terminal

(On Front Panel)

2

Grounding Cable (Not Supplied)

3

Metal Vehicle Frame

Connect cable from equipment

ground terminal to metal vehicle

frame. Use #10 AWG or larger insu-

lated copper wire.

Electrically bond generator frame to

vehicle frame by metal-to-metal contact.

GND/PE

1

2

3

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

Movement

5-1. Installing Welding Generator

OR

OR

Grounding

Y Bed liners, shipping skids, and some running

gears insulate the welding generator from the

vehicle frame. Always connect a ground wire

from the generator equipment grounding termi-

nal to bare metal on the vehicle frame as shown.

OR

Location/Airflow Clearance

OR