Safety instructions for the installer – Electrolux EHL 6645 X User Manual

Page 36

Advertising
background image

36

1

Safety Instructions for the Installer

• A device must be provided in the electrical installation which allows

the appliance to be disconnected from the mains at all poles with a
contact opening width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses
(screw type fuses are to be removed from the holder), earth leakage
trips and contactors.

• In respect of fire protection, this appliance corresponds to type Y

(EN 60 335-2-6). Only this type of appliance may be installed with a
high cupboard or wall on one side.

• Drawers may not be fitted underneath the hob.

• The installation must guarantee shock protection.

• The kitchen unit in which the appliance is fitted must satisfy the sta-

bility requirements of DIN 68930.

• For protection against moisture, all cut surfaces are to be sealed

with a suitable sealant.

• On tiled work surfaces, the joints in the area where the hob sits must

be completely filled with grout.

• On natural, artificial stone, or ceramic tops, the snap action springs

must be bonded in place with a suitable artificial resin or mixed ad-
hesive.

• Ensure that the seal is correctly seated in the frame and that it is

seated against the work surface without leaving any gaps. Addi-
tional silicon sealant must not be applied; this will make removal
more difficult when servicing.

• The hob must be pressed out from below when removed.

Advertising