5. installing gas supply – Miller Electric H-10 User Manual

Page 18

Advertising
background image

OM-219 316 Page 14

5-5. Installing Gas Supply

Obtain gas cylinder and chain to

running gear, wall, or other

stationary support so cylinder

cannot fall and break off valve.
1

Cap

2

Cylinder Valve

Remove cap, stand to side of valve,

and open valve slightly. Gas flow

blows dust and dirt from valve.

Close valve.
3

Cylinder

4

Regulator/Flowmeter

Install so face is vertical.
5

Regulator/Flowmeter Gas

Hose Connection

6

Welding Power Source Gas

Hose Connection

Connect supplied gas hose

between regulator/flowmeter gas

hose connection, and fitting on rear

of welding power source.
7

Flow Adjust

Turn flow adjust screw to increase

or decrease gas flow. Flow rate

should be set when gas is flowing

through welding power source and

welding gun. Turn Range switch to

Purge or Fan Only position. Press

gun trigger to start gas flow. Typical

flow rate is 20 cfh (cubic feet per

hour). Check wire manufacturer’s

recommended flow rate.

Tools Needed:

Ref. 802 028-A / 802 441 / Ref. 804 623-A

5/8, 1-1/8 in

.

DO NOT use Argon/Mixed gas regulator/flowmeter
with CO

2

shielding gas. See Parts List for optional

CO

2

gas regulator/flowmeter.

6

Argon Gas Or

Mixed Gas

Feedhead Pressure

Assembly Open

Feedhead Pressure

Assembly Closed

1

2

3

4

5

7