MPU-19

SWI INSTRUCTION

1.

Contents of the MPU registers PC, 1X, ACCA, ACCB and CC are stored in

RAM at the address indicated by the stack pointer in descending location

(7 bytes in all).

2.

The IRQ mask (bit I = 1) is set.

3.

Data at FFFA gets loaded into PCH.

4.

Data at FFFB gets loaded into PCL.

5.

PC contents go out on address bus during Ø1.

6.

Contents of cell addressed enters instruction register during Ø2 and is

decoded as first instruction of SWI subroutine.

7.

If it is a more than one byte instruction, additional bytes enter MPU

for execution. If not, go to next step.

8.

After execution, Step 6 is repeated for subsequent instructions. This

loop is repeated until the instruction "RTI" is executed.